OLIGOHYDRAMNIOS - MATERNAL COMPLICATIONS AND FETAL-OUTCOME IN 145 CASES

被引:27
作者
GOLAN, A [1 ]
LIN, G [1 ]
EVRON, S [1 ]
ARIELI, S [1 ]
NIV, D [1 ]
DAVID, MP [1 ]
机构
[1] SERLIN HOSP,TEL AVIV,ISRAEL
关键词
OLIGOHYDRAMNIOS; PREGNANCY COMPLICATIONS;
D O I
10.1159/000292532
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
One hundred and forty-five cases of oligohydramnios in the second and third trimester were diagnosed by ultrasonography out of 25,000 obstetrics patients (0.58%). In this group, pregnancy complications included hypertension (22.1%) and bleeding in the second trimester (4.1%). We found a high incidence of meconium-stained amniotic fluid (29.1%), fetal distress (7.9%) and premature placental separation (4.2%). IUGR occurred in 24.5% of cases. Asphyxia during labor occurred in 11.5% and different other perinatal problems in 23.5%. Cesarean section was performed in 35.2% of these pregnancies. Seventeen percent of the cases presented as breech. Intrauterine fetal death occurred in 5.5% of these pregnancies. The gross perinatal mortality was 16% and the corrected perinatal mortality was 10.7%. The overall rate of fetal malformations was 11% and that of lethal malformations 4.8%. The skeletal (7.6%) and urinary system (4.1%) were the predominant systems affected. Oligohydramnios is associated with a higher rate of pregnancy complications and increased fetal morbidity and mortality, and thus termination should be considered when pulmonary maturity is present or in cases of fetal distress.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 16 条
  • [1] ULTRASOUND EVALUATION OF AMNIOTIC-FLUID - OUTCOME OF PREGNANCIES WITH SEVERE OLIGOHYDRAMNIOS
    BASTIDE, A
    MANNING, F
    HARMAN, C
    LANGE, I
    MORRISON, I
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1986, 154 (04) : 895 - 900
  • [2] BENACERRAF BR, 1990, OBSTET GYNECOL, V75, P491
  • [3] ULTRASOUND EVALUATION OF AMNIOTIC-FLUID VOLUME .1. THE RELATIONSHIP OF MARGINAL AND DECREASED AMNIOTIC-FLUID VOLUMES TO PERINATAL OUTCOME
    CHAMBERLAIN, PF
    MANNING, FA
    MORRISON, I
    HARMAN, CR
    LANGE, IR
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 150 (03) : 245 - 249
  • [4] CROWLEY P, 1980, J PERINAT MED, V8, P249
  • [5] THE VALUE OF ULTRASOUND MEASUREMENT OF AMNIOTIC-FLUID VOLUME IN THE MANAGEMENT OF PROLONGED PREGNANCIES
    CROWLEY, P
    OHERLIHY, C
    BOYLAN, P
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (05): : 444 - 448
  • [6] ARTIFICIAL INSTILLATION OF AMNIOTIC-FLUID AS A NEW TECHNIQUE FOR THE DIAGNOSTIC EVALUATION OF CASES OF OLIGOHYDRAMNIOS
    GEMBRUCH, U
    HANSMANN, M
    [J]. PRENATAL DIAGNOSIS, 1988, 8 (01) : 33 - 45
  • [7] RELATIONSHIP BETWEEN AMNIOTIC-FLUID VOLUME AND MATERNAL PLASMA-VOLUME EXPANSION
    GOODLIN, RC
    ANDERSON, JC
    GALLAGHER, TF
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 146 (05) : 505 - 511
  • [8] HACKETT GA, 1987, BRIT J OBSTET GYNAEC, V94, P1974
  • [9] LOMBARDI SJ, 1989, OBSTET GYNECOL, V74, P338
  • [10] QUALITATIVE AMNIOTIC-FLUID VOLUME DETERMINATION BY ULTRASOUND - ANTEPARTUM DETECTION OF INTRAUTERINE GROWTH-RETARDATION
    MANNING, FA
    HILL, LM
    PLATT, LD
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 139 (03) : 254 - 258