Online conductivity monitoring of dialysis adequacy versus Kt/V derived from urea reduction ratio: A prospective study from a Saudi center

被引:0
作者
Al Saran, Khalid [1 ]
Sabry, Alaa [2 ]
Abdulghafour, Mamdouh [1 ]
Yehia, Ahmed [1 ]
机构
[1] Prince Salman Ctr Kidney Dis, Riyadh, Saudi Arabia
[2] Mansoura Univ, Mansoura Urol & Nephrol Ctr, Mansoura, Egypt
关键词
Kt/V; hemodialysis; online conductivity monitoring;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Ad equate delivered dose of solute removal (as assessed by urea reduction and calculation of Kt/V) is an important determinant of clinical outcome in chronic hemodialysis (HD) patients. This requires both prescription of an adequate dose of HD and regular assessment that the delivered treatments are also adequate. Online conductivity monitoring using sodium flux as a surrogate for urea allows the repeated noninvasive measurement of Kt/V on each HD treatment. Methods: We prospectively studied 17 (9 males, 8 females) established chronic HD patients over an eight- week period (408 treatments). A pre- and post- dialyzer measurement of the conductivity is performed by two mutually independent temperature- compensated conductivity cells equipped with Fresenius 4008 S-(R) dialysis machines. Urea reduction was measured (once a week) by a single pool calculation using immediate post- treatment sampling. No changes were made to any of the dialysis prescriptions over the study period. Values of calculated Kt/V and simultaneously obtained online Kt/V were compared. Results: There was a statistically significant difference between calculated Kt/V and online Kt/V over the study period. The mean calculated Kt/V was 1.37 +/- 0.09, and mean online Kt/V 1.02 +/- 0.15 (P = 0.000), calculated Kt/V > 1.2 was achieved in all our patients while online Kt/V. 1.2 was achieved in only 17.64 %. Yet there was moderate correlation between calculated Kt/V and online Kt/V (r(2) = 0.48). Conclusions: Online conductivity monitoring results underestimates dialysis efficiency compared to calculated Kt/V readings. This difference has to be considered when applying Kt/V to clinical practice.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 18 条
[1]  
[Anonymous], 2007, NEPHROL DIAL TRANSPL, V22, pii16
[2]   Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement [J].
Argiles, A ;
Ficheux, A ;
Thomas, M ;
Bosc, JY ;
Kerr, PG ;
Lorho, R ;
Flavier, JL ;
Stec, F ;
Adele, C ;
Leblanc, M ;
Garred, LJ ;
Canaud, B ;
Mion, H ;
Mion, CM .
KIDNEY INTERNATIONAL, 1997, 52 (02) :530-537
[3]  
DAUGIRDAS JT, 1993, J AM SOC NEPHROL, V4, P1205
[4]   A MECHANISTIC ANALYSIS OF THE NATIONAL COOPERATIVE DIALYSIS STUDY (NCDS) [J].
GOTCH, FA ;
SARGENT, JA .
KIDNEY INTERNATIONAL, 1985, 28 (03) :526-534
[5]   Evaluation of hemodialysis adequacy using online Kt/V and single-pool variable-volume urea Kt/V [J].
Grzegorzewska, Alicja E. ;
Banachowicz, Wojciech .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2008, 40 (03) :771-778
[6]  
HELD PJ, 1991, J AM SOC NEPHROL, V2, P238
[7]  
K-DOQI Clinical Practice Guidelines for Hemodialysis Adequacy, 2001, AM J KIDNEY DIS, V37, P179
[8]   Assessing dialysis adequacy and dietary intake in the individual hemodialysis patient [J].
Kloppenburg, WD ;
Stegeman, CA ;
Hooyschuur, M ;
van der Ven, J ;
de Jong, PE ;
Huisman, RM .
KIDNEY INTERNATIONAL, 1999, 55 (05) :1961-1969
[9]   Relationship between effective ionic dialysance and in vivo urea clearance during hemodialysis [J].
Lindsay, RM ;
Bene, B ;
Goux, N ;
Heidenheim, AP ;
Landgren, C ;
Sternby, J .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (03) :565-574
[10]   Ionic dialysance as a method for the on-line monitoring of delivered dialysis without blood sampling [J].
Manzoni, C ;
DiFilippo, S ;
Corti, M ;
Locatelli, F .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (10) :2023-2030