SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS

被引:171
作者
CONTURO, TE
SMITH, GD
机构
[1] VANDERBILT UNIV, DEPT RADIOL & RADIOL SCI, NASHVILLE, TN 37232 USA
[2] JOHNS HOPKINS MED INST, DEPT RADIOL & RADIOL SCI, BALTIMORE, MD 21205 USA
关键词
D O I
10.1002/mrm.1910150308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dynamic range of phase‐reconstructed magnetic resonance images is compared to that of magnitude‐reconstructed images. From analysis of propagation of errors, the phase angle noise is phase‐independent and given in radians by σ (|I|)/|I|, the noise‐to‐signal ratio of the corresponding magnitude‐reconstructed image. As the phase can range from minus π to π the phase angle dynamic range is 2π times that of the signal magnitude. These results agree with experiment, verifying that the noise in the two receiver channels is uncorrelated. An artifact‐free technique is presented for correcting phase spillover, which further extends the phase angle dynamic range. The reconstruction‐based reference phase is adjusted on a local basis so that the boundary of phase wraparound is reconstructed near the center of the [ − π, π] interval. For a particular flow study, the phase signal‐to‐noise was extended over twofold by spillover correction, to a value 15 times that of the magnitude signal‐to‐noise. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:420 / 437
页数:18
相关论文
共 48 条
[2]   RETRIEVAL OF FREQUENCIES, AMPLITUDES, DAMPING FACTORS, AND PHASES FROM TIME-DOMAIN SIGNALS USING A LINEAR LEAST-SQUARES PROCEDURE [J].
BARKHUIJSEN, H ;
DEBEER, R ;
BOVEE, WMMJ ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1985, 61 (03) :465-481
[3]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[4]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[5]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[6]   IMPROVED DETERMINATION OF SPIN-DENSITY, T1 AND T2 FROM A 3-PARAMETER FIT TO MULTIPLE-DELAY-MULTIPLE-ECHO (MDME) NMR IMAGES [J].
CONTURO, TE ;
PRICE, RR ;
BETH, AH ;
MITCHELL, MR ;
PARTAIN, CL ;
JAMES, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (12) :1361-1380
[7]   RAPID LOCAL RECTANGULAR VIEWS AND MAGNIFICATIONS - REDUCED PHASE ENCODING OF ORTHOGONALLY EXCITED SPIN ECHOES [J].
CONTURO, TE ;
PRICE, RR ;
BETH, AH .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :418-429
[8]   COOPERATIVE T1 AND T2 EFFECTS ON CONTRAST USING A NEW DRIVEN INVERSION SPIN-ECHO (DISE) MRI PULSE SEQUENCE [J].
CONTURO, TE ;
KESSLER, RM ;
BETH, AH .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :397-419
[9]  
CONTURO TE, 1987, SOC MAGN RESON MED, P25
[10]  
CONTURO TE, 1987, SOC MAGN RESON MED B, P909