A BODY-WORN GAIT ANALYSIS SYSTEM FOR EVALUATING HEMIPLEGIC GAIT

被引:17
|
作者
GRANAT, MH
MAXWELL, DJ
BOSCH, CJ
FERGUSON, ACB
LEES, KR
BARBENEL, JC
机构
[1] UNIV TWENTE,DIV BIOMED ENGN,7500 AE ENSCHEDE,NETHERLANDS
[2] WESTERN INFIRM & ASSOCIATED HOSP,GARDINER INST,DEPT MED & THERAPEUT,GLASGOW G11 6NT,LANARK,SCOTLAND
关键词
GAIT; HEMIPLEGIA; TEMPORAL PARAMETERS; INSOLES;
D O I
10.1016/1350-4533(95)97321-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a system for measuring the temporal parameters of hemiplegic gait. This system uses shoe insoles with sensors, acting as switches, placed under the heel, head of the first metatarsal, head of the fifth metatarsal and the big toe. This system is able to monitor gait for up to 10 min and can be used by the patient over any surface. Parameters for evaluating hemiplegic gait are defined including scuffing during swing and the degree of inversion. during stance.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [1] Objective Biomarkers of Balance and Gait for Parkinson's Disease Using Body-worn Sensors
    Horak, Fay B.
    Mancini, Martina
    MOVEMENT DISORDERS, 2013, 28 (11) : 1544 - 1551
  • [2] KINEMATIC GAIT ANALYSIS IN HEMIPLEGIC PATIENTS
    OZGIRGIN, N
    BOLUKBASI, N
    BEYAZOVA, M
    ORKUN, S
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1993, 25 (02): : 51 - 55
  • [3] Assessment of hemiplegic gait using the Wisconsin Gait Scale
    Turani, N
    Kemiksizoglu, A
    Karatas, M
    Özker, R
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2004, 18 (01) : 103 - 108
  • [4] Body-worn sensors capture variability, but not decline, of gait and balance measures in multiple sclerosis over 18 months
    Spain, Rebecca I.
    Mancini, Martina
    Horak, Fay B.
    Bourdette, Dennis
    GAIT & POSTURE, 2014, 39 (03) : 958 - 964
  • [5] GAIT ANALYSIS OF HEMIPLEGIC PATIENTS BY MEASUREMENT OF GROUND REACTION FORCE
    MORITA, S
    YAMAMOTO, H
    FURUYA, K
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1995, 27 (01): : 37 - 42
  • [6] Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed
    Spain, R. I.
    George, R. J. St.
    Salarian, A.
    Mancini, M.
    Wagner, J. M.
    Horak, F. B.
    Bourdette, D.
    GAIT & POSTURE, 2012, 35 (04) : 573 - 578
  • [7] The parameters of gait analysis related to ambulatory and balance functions in hemiplegic stroke patients: a gait analysis study
    Chang, Min Cheol
    Lee, Byung Joo
    Joo, Na-Young
    Park, Donghwi
    BMC NEUROLOGY, 2021, 21 (01)
  • [8] Assessment of gait parameter in hemiplegic patients by accelerometry
    Sekine, M
    Abe, Y
    Sekimoto, M
    Higashi, Y
    Fujimoto, T
    Tamura, T
    Fukui, Y
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1879 - 1882
  • [9] A study of the effect of cyproheptadine on gait in hemiplegic children
    Khodadadeh, S
    Holstein, H
    Purushothaman, S
    Patrick, J
    GAIT & POSTURE, 1998, 8 (03) : 205 - 213
  • [10] The parameters of gait analysis related to ambulatory and balance functions in hemiplegic stroke patients: a gait analysis study
    Min Cheol Chang
    Byung Joo Lee
    Na-Young Joo
    Donghwi Park
    BMC Neurology, 21