TRACE ANALYSIS USING POSITION-SENSITIVE DETECTION IN MAGNETIC-SECTOR MASS-SPECTROMETRY

被引:0
|
作者
WATSON, LR [1 ]
THIEM, TL [1 ]
DRESSLER, RA [1 ]
SALTER, RH [1 ]
MURAD, E [1 ]
机构
[1] WSSI, PHILLIPS LAB, BEDFORD, MA 01731 USA
关键词
MASS SPECTROSCOPY; POSITION-SENSITIVE ION DETECTION; TRACE ANALYSIS;
D O I
10.1080/00387019308011560
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A position-sensitive ion detection system for trace analysis with magnetic sector mass spectrometers is described in detail, with particular application to high temperature mass spectrometry. The detection system consists of two stacked microchannel plates (Chevron assembly) backed by a resistive anode encoder and associated electronics. The range of masses simultaneously detectable is m to 1.2m. For election impact ionization of silver at an electron energy of 10.5 eV, the sensitivity is 1.6 x 10(-7) pa, and the mass resolution is 260 at mass 80 (valley 10% of the peak height definition). Additional applications for the detection system are discussed.
引用
收藏
页码:661 / 676
页数:16
相关论文
共 50 条
  • [31] TANDEM MASS-SPECTROMETRY IN TRACE TOXICANT ANALYSIS
    MCLAFFERTY, FW
    BIOMEDICAL MASS SPECTROMETRY, 1981, 8 (09): : 446 - 448
  • [32] MASS-SPECTROMETRY AND TRACE ANALYSIS OF FOOD CONTAMINANTS
    GILBERT, J
    STARTIN, JR
    CREWS, C
    JOURNAL OF THE ASSOCIATION OF PUBLIC ANALYSTS, 1985, 23 : 119 - 131
  • [33] STRUCTURAL ELUCIDATION AND TRACE ANALYSIS WITH COMBINED HYPHENATED CHROMATOGRAPHIC AND MASS-SPECTROMETRIC METHODS - POTENTIAL OF USING HYBRID SECTOR MASS-SPECTROMETRY TIME-OF-FLIGHT MASS-SPECTROMETRY FOR PESTICIDE ANALYSIS
    SCHUTZ, S
    HUMMEL, HE
    DUHR, A
    WOLLNIK, H
    JOURNAL OF CHROMATOGRAPHY A, 1994, 683 (01) : 141 - 149
  • [34] IMPROVED LEED SYSTEM USING POSITION-SENSITIVE DETECTION
    MALIC, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09): : 1951 - 1953
  • [35] IMPROVED THERMOSPRAY ACCURATE MASS MEASUREMENT USING A MAGNETIC-SECTOR INSTRUMENT
    DAVIDSON, WC
    DINALLO, RM
    HANSEN, GE
    BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (06) : 389 - 391
  • [36] Depth profiling of ultrashallow B implants in silicon using a magnetic-sector secondary ion mass spectrometry instrument
    Napolitani, E
    Carnera, A
    Storti, R
    Privitera, V
    Priolo, F
    Mannino, G
    Moffatt, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2000, 18 (01): : 519 - 523
  • [37] Theoretical noise analysis on a position-sensitive Metallic Magnetic Calorimeter
    Smith, S. J.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [38] APPLICATIONS OF MASS-SPECTROMETRY TO TRACE ANALYSIS - FACCHETTI,S
    HARRISON, WW
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (26) : 7796 - 7797
  • [39] TRACE-ELEMENT ANALYSIS BY ACCELERATOR MASS-SPECTROMETRY
    MCDANIEL, FD
    MATTESON, S
    ANTHONY, JM
    WEATHERS, DL
    DUGGAN, JL
    MARBLE, DK
    HASSAN, I
    ZHAO, ZY
    ARRALE, AM
    KIM, YD
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 167 (02): : 423 - 432
  • [40] TRACE SILVER ANALYSIS BY SECONDARY ION MASS-SPECTROMETRY
    CHRYSSOULIS, SL
    CHAUVIN, W
    SURGES, LJ
    CIM BULLETIN, 1985, 78 (878): : 77 - 77