THE USE OF LIQUIDS IN IONIZATION CHAMBERS FOR HIGH-PRECISION RADIOTHERAPY DOSIMETRY

被引:59
|
作者
WICKMAN, G
NYSTROM, H
机构
[1] Dept. of Radiat. Phys., Umea Univ.
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1992年 / 37卷 / 09期
关键词
D O I
10.1088/0031-9155/37/9/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two dielectric liquids, isooctane and tetramethylsilane (TMS) have been tested as sensitive media in parallel-plate ionization chambers. The ionization chambers use graphite electrodes and have a high spatial resolution due to a coin-shaped ionization volume of 2 mm3 (diameter 3 mm, height 0.3 mm). The detectors show a calibration stability within +/-1% over several years. After a single very large absorbed dose of 10 kGy a sensitivity loss of about 0.1% was found in TMS while the corresponding loss was about 2% in isooctane. In neither of the liquids did general recombination exceed 2% in pulsed radiation fields and dose rates up to 7 Gy min-1 (PRF = 200 s-1, and dose per pulse = 0.6 mGy). Residual current, reproducibility and sensitivity are more favourable in TMS than in isooctane. The absorbed dose to water calibration factors at various radiotherapy qualities were determined by the use of FeSO4 dosimetry as a reference. A weak, hardly resolvable difference in the calibration factor was found in the TMS chambers, and in the isooctane chambers this was within 3%. However, the boiling point of TMS is low, and this restricts its upper operational temperature to about 26-degrees-C.
引用
收藏
页码:1789 / 1812
页数:24
相关论文
共 50 条
  • [31] ASPECTS IN PRACTICAL NEUTRON DOSIMETRY WITH IONIZATION CHAMBERS
    KUHN, H
    BIOPHYSIK, 1973, 10 (03): : 229 - 234
  • [32] Diagnostic radiology dosimetry using ionization chambers
    Albuquerque, MD
    Caldas, LVE
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C455 - C457
  • [33] High-precision accounting for high-precision network services
    Clemm, Alexander
    Strassner, John
    2021 IEEE 22ND INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE SWITCHING AND ROUTING (IEEE HPSR), 2021,
  • [34] EMI SCANNER HELPS ICR GIVE HIGH-PRECISION RADIOTHERAPY
    不详
    ELECTRONICS AND POWER, 1978, 24 (07): : 530 - 530
  • [35] HIGH-PRECISION MILLING - USE OF STATUS CONTROLLERS
    RUDLOFF, H
    KETTERER, G
    FINGERBERG, W
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1991, 81 (02): : 91 - 93
  • [36] Use of linear motors for high-precision displacements
    Minciunescu, Paul
    Vasile, Iulian
    Romanian Review Precision Mechanics, Optics and Mechatronics, 2010, (38): : 75 - 78
  • [37] The university of Florida frameless high-precision stereotactic radiotherapy system
    Bova, FJ
    Buatti, JM
    Friedman, WA
    Mendenhall, WM
    Yang, CC
    Liu, C
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04): : 875 - 882
  • [38] Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy
    Hirata, Makoto
    Monzen, Hajime
    Tamura, Mikoto
    Kubo, Kazuki
    Matsumoto, Kenji
    Hanaoka, Kohei
    Okumura, Masahiko
    Nishimura, Yasumasa
    ANTICANCER RESEARCH, 2018, 38 (05) : 2733 - 2738
  • [39] Design and calibration of the attix plane parallel plate ionization chambers and their use in electron dosimetry
    Constantinou, C
    Song, L
    Vecris, G
    DeWerd, LA
    Micka, JA
    Harrington, JC
    PATRAS MEDICAL PHYSICS 99, 1999, : 135 - 142
  • [40] THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS
    ALMOND, PR
    XU, ZG
    PARK, HC
    MEDICAL PHYSICS, 1995, 22 (08) : 1307 - 1314