THE USE OF LIQUIDS IN IONIZATION CHAMBERS FOR HIGH-PRECISION RADIOTHERAPY DOSIMETRY

被引:59
|
作者
WICKMAN, G
NYSTROM, H
机构
[1] Dept. of Radiat. Phys., Umea Univ.
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1992年 / 37卷 / 09期
关键词
D O I
10.1088/0031-9155/37/9/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two dielectric liquids, isooctane and tetramethylsilane (TMS) have been tested as sensitive media in parallel-plate ionization chambers. The ionization chambers use graphite electrodes and have a high spatial resolution due to a coin-shaped ionization volume of 2 mm3 (diameter 3 mm, height 0.3 mm). The detectors show a calibration stability within +/-1% over several years. After a single very large absorbed dose of 10 kGy a sensitivity loss of about 0.1% was found in TMS while the corresponding loss was about 2% in isooctane. In neither of the liquids did general recombination exceed 2% in pulsed radiation fields and dose rates up to 7 Gy min-1 (PRF = 200 s-1, and dose per pulse = 0.6 mGy). Residual current, reproducibility and sensitivity are more favourable in TMS than in isooctane. The absorbed dose to water calibration factors at various radiotherapy qualities were determined by the use of FeSO4 dosimetry as a reference. A weak, hardly resolvable difference in the calibration factor was found in the TMS chambers, and in the isooctane chambers this was within 3%. However, the boiling point of TMS is low, and this restricts its upper operational temperature to about 26-degrees-C.
引用
收藏
页码:1789 / 1812
页数:24
相关论文
共 50 条
  • [1] USE OF IONIZATION CHAMBERS IN HIGH ENERGY ELECTRON DOSIMETRY
    KARTHA, M
    MACDONAL.JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 134 - &
  • [2] Evolution of radiotherapy: High-precision radiotherapy
    Kim, Yong Bae
    Suh, Chang-Ok
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2008, 51 (07): : 604 - 611
  • [3] DOSIMETRY WITH IONIZATION CHAMBERS FOR A FAST-NEUTRON RADIOTHERAPY FACILITY
    BICHSEL, H
    EENMAA, J
    SCHUMACH.D
    WILLIAMS, DL
    WOOTTON, P
    WYCKOFF, WG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 579 - 579
  • [4] Calibration of the TWIST high-precision drift chambers
    Grossheim, A.
    Hu, J.
    Olin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (03): : 954 - 959
  • [5] Development of novel ionization chambers for reference dosimetry in electron flash radiotherapy
    Liu, Kevin
    Holmes, Shannon
    Khan, Ahtesham Ullah
    Hooten, Brian
    DeWerd, Larry
    Schuler, Emil
    Beddar, Sam
    MEDICAL PHYSICS, 2024, : 9275 - 9289
  • [6] IONIZATION CHAMBERS FOR ELECTRON DOSIMETRY BELOW 10 MEV FOR RADIOTHERAPY PURPOSES
    MATTSSON, LO
    JOHANSSON, KA
    SVENSSON, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 764 - 764
  • [7] A HIGH-PRECISION SILICON DIODE DOSIMETRY SYSTEM
    DIXON, RL
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 303 - 306
  • [8] Imaging for high-precision thoracic radiotherapy
    Senthi, Sashendra
    Senan, Suresh
    JOURNAL OF THORACIC DISEASE, 2012, 4 (02) : 106 - 108
  • [9] IONIZATION CHAMBERS FOR ELECTRON DOSIMETRY
    BOAG, JW
    PILLING, FD
    WILSON, T
    BRITISH JOURNAL OF RADIOLOGY, 1951, 24 (282): : 341 - 344
  • [10] USE OF IONIZATION CHAMBERS FILLED WITH A DIELECTRIC LIQUID IN RADIATION DOSIMETRY
    LADU, M
    PELLICCIONI, M
    NUCLEAR INSTRUMENTS & METHODS, 1967, 53 (01): : 35 - +