VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE

被引:6
|
作者
Devnani, H. [1 ]
Singh, P. [1 ]
Saxena, S. [1 ]
Satsangee, S. P. [1 ]
机构
[1] Dayalbagh Educ Inst, Univ Sci Instrumentat Ctr, Agra 282005, UP, India
关键词
Rupatadine; Graphene; Voltammetry; Electrochemical Impedance;
D O I
10.13040/IJPSR.0975-8232.5(11).4792-99
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Electrochemical behavior of rupatadine, an anti- allergic drug was studied at graphene modified glassy carbon electrode in Britton-Robinson buffer (pH 6.5) by square wave voltammetry (frequency, 50 Hz; amplitude, 0.02 V; step potential, 0.005 V) and cyclic voltammetry (scan rates, 20- 100 mV/s) techniques. Cyclic voltammetry revealed the oxidation of rupatadine corresponding to N-dealkylation which is the major metabolic pathway of rupatadine in human body. Atomic force microscopy, scanning electron microscopy and electrochemical impedance spectroscopy were used to study the surface characteristics of the fabricated sensor. The electrode dynamic parameters were investigated and the oxidation mechanism was proposed. Lower limit of detection and quantification were achieved with the modified sensor as compared to the bare sensor due to enhancement in electron transfer process at the surface of modified sensor owing to greater electroactive surface area. The limit of detection was found to be 56.78 ng/ml and limit of quantification, 172.06 ng/ml at graphene modified glassy carbon electrode.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [2] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    Microchimica Acta, 2016, 183 : 1459 - 1467
  • [3] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467
  • [4] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [5] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    Analytical Sciences, 2012, 28 : 497 - 502
  • [6] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [7] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [8] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [9] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [10] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144