Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients

被引:8
作者
Fanihagh, Farsad [1 ]
Kremmer, Stephan [1 ,2 ]
Anastassiou, Gerasimos [1 ,2 ]
Schallenberg, Maurice [2 ,3 ]
Steuhl, Klaus-Peter [2 ]
Selbach, Michael [1 ,2 ]
机构
[1] Evangel Krankenhaus Gelsenkirchen, Dept Ophthalmol, Munckelstr 27, D-45879 Gelsenkirchen, Germany
[2] Univ Duisburg Essen, Dept Ophthalmol, D-45122 Essen, Germany
[3] HELIOS Klinikum Wuppertal, Eye Hosp, D-42283 Wuppertal, Germany
关键词
Confocal scanning laser ophthalmoscopy; glaucoma; OCT; retinal nerve fiber layer; scanning laser polarimetry;
D O I
10.2174/1874364101509010041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). Materials and Methodology: 114 eyes of patients with moderate open angle glaucoma underwent spectral domain OCT (Topcon SD-OCT 2000 and Zeiss Cirrus HD-OCT), SLP (GDx VCC and GDx Pro) and CSLO (Heidelberg Retina Tomograph, HRT 3). Correlation coefficients were calculated between the structural parameters yielded by these examinations. The quantitative relationship between the measured RNFL thickness globally and for the four regions (superior, inferior, nasal, temporal) were evaluated with different regression models for all used imaging systems. Results: The strongest correlation of RNFL measurements was found between devices using the same technology like GDx VCC and GDx Pro as well as Topcon OCT and Cirrus OCT. In glaucoma patients, the strongest associations (R-2) were found between RNFL measurements of the two optical coherence tomography devices Topcon OCT and Cirrus OCT (R-2 = 0.513) and between GDx VCC and GDx Pro (R2 = 0.451). The results of the OCTs and GDX Pro also had a strong quantitative relationship (Topcon OCT R-2 = 0.339 and Cirrus OCT R-2 = 0.347). GDx VCC and the OCTs showed a mild to moderate association (Topcon OCT R-2 = 0.207 and Cirrus OCT R-2 = 0.258). The confocal scanning laser ophthalmoscopy (HRT 3) had the lowest association to all other devices (Topcon OCT R-2 = 0.254, Cirrus OCT R-2 = 0.158, GDx Pro R-2 = 0.086 and GDx VCC R-2 = 0.1). Conclusion: The measurements of the RNFL in glaucoma patients reveal a high correlation of OCT and GDx devices because OCTs can measure all major retinal layers and SLP can detect nerve fibers allowing a comparison between the results of this devices. However, CSLO by means of HRT topography can only measure height values of the retinal surface but it cannot distinguish between different retinal layers. This may explain the rather poor correlations and associations between CSLO measurements and those of all other imaging devices which makes it difficult to compare HRT 3 nerve fiber data. These correlations are important in clinical routine especially when different techniques are used in the follow-up of glaucoma patients.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 22 条
[1]   Variation in Optic Nerve and Macular Structure with Age and Race with Spectral-Domain Optical Coherence Tomography [J].
Girkin, Christopher A. ;
McGwin, Gerald, Jr. ;
Sinai, Micheal J. ;
Sekhar, G. Chandra ;
Fingeret, Murrey ;
Wollstein, Gadi ;
Varma, Rohit ;
Greenfield, David ;
Liebmann, Jeffery ;
Araie, Makoto ;
Tomita, Goji ;
Maeda, Naoyuki ;
Garway-Heath, David F. .
OPHTHALMOLOGY, 2011, 118 (12) :2403-2408
[2]   Ophthalmoscopic evaluation of the optic nerve head [J].
Jonas, JB ;
Budde, WM ;
Panda-Jonas, S .
SURVEY OF OPHTHALMOLOGY, 1999, 43 (04) :293-320
[3]  
Karmeyer H., 1977, DOC OPHTHALMOL P SER, V14, P75
[4]  
Kerrigan-Baumrind LA, 2000, INVEST OPHTH VIS SCI, V41, P741
[5]   Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT [J].
Knight, O'Rese J. ;
Girkin, Christopher A. ;
Budenz, Donald L. ;
Durbin, Mary K. ;
Feuer, William J. .
ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (03) :312-318
[6]   Scanning laser polarimetry in myopic and hyperopic subjects [J].
Kremmer, S ;
Zadow, T ;
Steuhl, KP ;
Selbach, JM .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 242 (06) :489-494
[7]  
Kremmer S., 2011, GLAUKOM UND MAKULA, P15
[8]   Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head [J].
Kremmer, Stephan ;
Keienburg, Marcus ;
Anastassiou, Gerasimos ;
Schallenberg, Maurice ;
Steuhl, Klaus-Peter ;
Selbach, J. Michael .
OPEN OPHTHALMOLOGY JOURNAL, 2012, 6 :6-16
[9]   Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography: Interpreting the RNFL Maps in Healthy Myopic Eyes [J].
Leung, Christopher Kai-Shun ;
Yu, Marco ;
Weinreb, Robert N. ;
Mak, Heather Kayew ;
Lai, Gilda ;
Ye, Cong ;
Lam, Dennis Shun-Chiu .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) :7194-7200
[10]   Evaluation of Retinal Nerve Fiber Layer Progression in Glaucoma A Comparison between Spectral-Domain and Time-Domain Optical Coherence Tomography [J].
Leung, Christopher Kai-Shun ;
Chiu, Vivian ;
Weinreb, Robert N. ;
Liu, Shu ;
Ye, Cong ;
Yu, Marco ;
Cheung, Carol Yim-lui ;
Lai, Gilda ;
Lam, Dennis Shun-Chiu .
OPHTHALMOLOGY, 2011, 118 (08) :1558-1562