THE POLAROGRAPHIC-DETERMINATION OF FLUVOXAMINE MALEATE

被引:7
作者
TUNCEL, M
ALTIOKKA, G
ATKOSAR, Z
机构
[1] Department of Analytical Chemistry, University of Anadolu, 26470, Eskisehir
关键词
POLAROGRAPHY OF FLUVOXAMINE; DETERMINATION OF FLUVOXAMINE; PHARMACEUTICAL APPLICATION;
D O I
10.1080/00032719408000284
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the polarographic behaviour and the optimum polarographic conditions for the determination of fluvoxamine using DC, DP and SIAP techniques are described based on the reduction on the DME. The experiments were conducted in the aqueous supporting electrolyte containing 0.2 M KCI, 20 % ethanol (v/v) and 0.2 M buffer solution. Single waves were obtained at various pH values. The limiting currents were decreased and E(1/2) values were linearly shifted to more negative potentials with an increase of pH. The system was irreversible at both the acidic and the basic medium and was controlled by adsorption at pH 4.2 and by diffusion at pH 8.03. The variation of the limiting current against temperature was found to be 1.1 mu A/degrees C. Good calibration relations were obtained for DC (direct current), DP (differential pulse) and SIAP (superimposed increasing amplitude pulse) techniques. The determination of fluvoxamine in a pharmaceutical preparation, Faverin(R) Tablets containing 50 mg of fluvoxamine, were tested. The results were compared to those of UV-spectrophotometric method. In the analysis of a single 50 mp tablet, the relative standard deviation (S-rel) are found to be between +/-0.5 and +/-1.0 for the techniques employed for filtered and unfiltered solutions. The polarographic techniques used for the determination of fluvoxamine seem to be accurate, rapid and practical. Therefore, the suggested method may be promising in the routine analysis.
引用
收藏
页码:1135 / 1145
页数:11
相关论文
共 10 条
[1]  
BAUER HH, 1978, INSTRUMENTAL ANAL, P56
[2]   DIAGNOSIS OF REVERSIBLE, QUASI-REVERSIBLE, AND IRREVERSIBLE ELECTRODE PROCESSES WITH DIFFERENTIAL PULSE POLAROGRAPHY [J].
BIRKE, RL ;
KIM, MH ;
STRASSFELD, M .
ANALYTICAL CHEMISTRY, 1981, 53 (06) :852-856
[3]   FLUVOXAMINE, A SPECIFIC 5-HYDROXYTRYPTAMINE UPTAKE INHIBITOR [J].
CLAASSEN, V ;
DAVIES, JE ;
HERTTING, G ;
PLACHETA, P .
BRITISH JOURNAL OF PHARMACOLOGY, 1977, 60 (04) :505-516
[4]   RAPID MEASUREMENT OF BASIC DRUGS IN BLOOD APPLIED TO CLINICAL AND FORENSIC TOXICOLOGY [J].
DAWLING, S ;
WARD, N ;
ESSEX, EG ;
WIDDOP, B .
ANNALS OF CLINICAL BIOCHEMISTRY, 1990, 27 :473-477
[5]   THE USE OF A PRE-COLUMN FOR THE DIRECT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE ANTI-DEPRESSANTS CLOVOXAMINE AND FLUVOXAMINE IN PLASMA [J].
DEJONG, GJ .
JOURNAL OF CHROMATOGRAPHY, 1980, 183 (02) :203-211
[6]   DETERMINATION OF FLUVOXAMINE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
FOGLIA, JP ;
BIRDER, LA ;
PEREL, JM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 :295-302
[7]   IDENTIFICATION OF DRUGS IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION AND A SEARCH ALGORITHM FOR ULTRAVIOLET-SPECTRA [J].
MINDER, EI ;
SCHAUBHUT, R ;
MINDER, CE ;
VONDERSCHMITT, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :135-154
[8]  
NEINGER P, 1990, J ANAL TOXICOL, V14, P219
[9]   FLUOROMETRIC-DETERMINATION OF FLUVOXAMINE OR CLOVOXAMINE IN HUMAN-PLASMA AFTER THIN-LAYER CHROMATOGRAPHIC OR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION [J].
SCHWEITZER, C ;
SPAHN, H ;
MUTSCHLER, E .
JOURNAL OF CHROMATOGRAPHY, 1986, 382 :405-411
[10]   POLAROGRAPHIC AND VOLTAMMETRIC METHODS IN PHARMACEUTICAL CHEMISTRY AND PHARMACOLOGY [J].
VOLKE, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1983, 10 (01) :7-23