THE RESULTS OF MASS TESTING OF THE PLASTIC STREAMER TUBES FOR THE DELPHI HADRON CALORIMETER

被引:1
|
作者
ALEKSEEV, GD
BONUSHKIN, YY
CZELLAR, S
FIALOVSZKI, B
KHOMENKO, BA
KHOVANSKY, NN
KORYTOV, AV
KULINICH, PA
LOKAJICEK, M
MITSELMAKHER, GD
PATOCKA, J
RYABTSOV, VD
RIDKY, J
SEDYKH, YV
TOKMENIN, VV
TOLEDO, R
TARJAN, E
机构
[1] Laboratory of Nuclear Problems, Joint Institute for Nuclear Research, Moscow
关键词
D O I
10.1016/0168-9002(91)90550-A
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The procedure and results of mass testing of plastic streamer tubes for the DELPHI hadron calorimeter are described in detail. The mass testing includes three stages: high voltage test and conditioning, X-ray test on radiation load capability and wire tension control in ready detectors. The productivity of the test workshop was 240 detectors per day at maximum. After testing of about 25 000 streamer tubes, 8% have been rejected on the ground of severe rejection criteria which exceed significantly the working conditions in the DELPHI experiment.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 50 条
  • [21] STUDY OF SPACE RESOLUTION OF PLASTIC STREAMER TUBES
    GOLUTVIN, IA
    DODOKHOV, VK
    KARZHAVIN, VY
    KIRYUSHIN, YT
    KOMOGOROVA, LV
    LYSYAKOV, VN
    POZE, D
    RIEMANN, S
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (01) : 44 - 48
  • [22] DIGITAL READOUT OF COSMIC EVENTS IN PLASTIC STREAMER TUBES
    BRINKER, F
    HARTZ, PH
    RAUSCHNABEL, K
    WALTHER, A
    HELVETICA PHYSICA ACTA, 1987, 60 (5-6): : 757 - 757
  • [23] A detector of electromagnetic showers on the basis of plastic streamer tubes
    Belousov, VI
    Chuiko, BV
    Konstantinov, AS
    Kotov, IV
    Tsay, OD
    Vasiliev, AN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (01): : 45 - 49
  • [24] RESULTS FROM A TEST OF AN IRON STREAMER TUBE CALORIMETER
    BRAUNSCHWEIG, W
    GENZEL, H
    KIRSCHFINK, FJ
    ROHNER, M
    TUTAS, J
    VOGEL, E
    WIDGOFF, M
    BRASSE, FW
    FLAUGER, W
    GAYLER, J
    KORBEL, V
    MARKS, J
    ZEITNITZ, C
    BRINKER, F
    BRINKMANN, S
    HARTZ, P
    RAUSCHNABEL, K
    WALTHER, A
    WEGENER, D
    BARRELET, E
    BRISSON, V
    LELLOUCH, D
    PERRODO, P
    VALLEE, C
    CAMPBELL, AJ
    BLUME, HT
    LAU, K
    LIPP, F
    WEINSTEIN, R
    GREIF, H
    HUBER, J
    KIESLING, C
    LUERS, D
    OBERLACK, H
    SCHACHT, P
    VONGOELER, E
    MOROMISATO, J
    DELCOURT, B
    JACHOLKOWSKA, A
    DUBOC, J
    NGUYEN, H
    BIDOLI, V
    FERRAROTTO, F
    STELLA, B
    BESANCON, M
    COZZIKA, G
    DAVID, M
    FELTESSE, J
    DELESQUEN, A
    VERRECCHIA, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (2-3): : 334 - 346
  • [25] STUDY OF SPACE RESOLUTION OF PLASTIC STREAMER TUBES.
    Golutvin, I.A.
    Dodokhov, V.Kh.
    Karzhavin, V.Yu.
    Kiryushin, Yu.T.
    Komogorova, L.V.
    Lysyakov, V.N.
    Poze, D.
    Reimann, S.
    Instruments and experimental techniques New York, 1987, 30 (1 pt 1): : 44 - 48
  • [26] Detector of electromagnetic showers on the basis of plastic streamer tubes
    Nucl Instrum Methods Phys Res Sect A, 1 (45):
  • [27] Detector of electromagnetic showers using plastic streamer tubes
    Belousov, VI
    Vasilev, AN
    Konstantinov, AS
    Kotov, IV
    Tsai, OL
    Chuiko, BV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1995, 38 (04) : 434 - 437
  • [28] Electromagnetic shower detector on the base of plastic streamer tubes
    Belousov, V.I.
    Vasil'ev, A.N.
    Konstantinov, A.S.
    Kotov, I.V.
    Tsaj, O.D.
    Chujko, B.V.
    Pribory i Tekhnika Eksperimenta, 1995, (04): : 21 - 26
  • [29] PROPORTIONAL TUBE ELECTROMAGNETIC CALORIMETER WITH CONDUCTIVE PLASTIC TUBES
    ATAC, M
    YAMADA, R
    TAKASAKI, F
    MISHINA, M
    OGAWA, K
    HAYASHIDE, Y
    KIM, S
    KONDO, K
    MIYASHITA, S
    MIYATA, H
    SATO, F
    YASU, Y
    YOSHINO, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 368 - 372
  • [30] A GAS SAMPLING CALORIMETER USING CONDUCTIVE PLASTIC TUBES
    HAYASHIDE, Y
    KIM, S
    KONDO, K
    MIYASHITA, S
    MIYATA, H
    SATO, F
    YAMASHITA, A
    YASU, Y
    YOSHINO, M
    MISHINA, M
    OGAWA, K
    TAKASAKI, F
    ATAC, M
    YAMADA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 204 (2-3): : 361 - 369