MODEL OF THE SPATIAL-FREQUENCY-DEPENDENT DETECTIVE QUANTUM EFFICIENCY OF PHOSPHOR SCREENS

被引:110
作者
NISHIKAWA, RM
YAFFE, MJ
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M4X 1K9,ONTARIO,CANADA
[2] ONTARIO CANC INST,DIV PHYS,TORONTO M4X 1K9,ONTARIO,CANADA
[3] UNIV TORONTO,TORONTO GEN HOSP,RB HOLMES RADIOL RES LABS,TORONTO M4X 1K9,ONTARIO,CANADA
关键词
detective quantum efficiency; fluorescent screens;
D O I
10.1118/1.596583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a theoretical model to predict the modulation transfer function (MTF), the shape of the x-ray quantum noise power spectrum (NPS), and the spatial-frequency-dependent detective quantum efficiency (DQE) of an x-ray phosphor screen. The transfer of energy through the screen is modelled as a series of cascaded stochastic processes assuming that the screen consists of many thin phosphor layers. In this way, the model is able to account for the possibility of secondary-quantum noise and the difference in shape between MTF2 and the x-ray quantum NPS. Modelling a Kodak Min-R screen we were able to predict both the number of light quanta emitted per absorbed x-ray and MTF(f) to better than ± 5%, and the scintillation efficiency to within 10% of experimentally measured values. The shape of the x-ray quantum NPS is predicted to within + 5% for spatial frequencies less than about 6 mm'1and to within + 20% for higher frequencies. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:894 / 904
页数:11
相关论文
共 38 条
[1]   RADIOGRAPHIC MOTTLE - A COMPREHENSIVE THEORY [J].
BARNES, GT .
MEDICAL PHYSICS, 1982, 9 (05) :656-667
[2]  
BENDAT JS, 1986, RANDOM DATA, P280
[3]  
BIRCH R, 1979, HPA SCI REPORT SERIE, V33
[4]   ANALYSIS OF THE DETECTIVE QUANTUM EFFICIENCY OF A RADIOGRAPHIC SCREEN FILM COMBINATION [J].
BUNCH, PC ;
HUFF, KE ;
VANMETTER, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :902-909
[5]  
BUNCH PC, COMMUNICATION
[6]  
DAINTY JC, 1974, IMAGE SCI, P222
[7]   IMAGE-INFORMATION TRANSFER PROPERTIES OF X-RAY FLUORESCENT SCREENS [J].
DICK, CE ;
MOTZ, JW .
MEDICAL PHYSICS, 1981, 8 (03) :337-346
[8]   UTILIZATION OF MONOENERGETIC X-RAY-BEAMS TO EXAMINE THE PROPERTIES OF RADIOGRAPHIC INTENSIFYING SCREENS [J].
DICK, CE ;
MOTZ, JW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (02) :1554-1558
[9]  
DOI K, 1982, HHS FDA828187 PUBL
[10]   OPTICAL FACTORS AFFECTING THE DETECTIVE QUANTUM EFFICIENCY OF RADIOGRAPHIC SCREENS [J].
DRANGOVA, M ;
ROWLANDS, JA .
MEDICAL PHYSICS, 1986, 13 (02) :150-157