Electric Potential of Various 4-electrode Segmentation Excitation for Electrical Capacitance Tomography System

被引:0
作者
Din, Shahrulnizahani Mohammad [1 ]
Azmi, Aizat [1 ]
Song, Chee Pei [1 ]
Rahim, Ruzairi Abdul [1 ]
Ling, Leow Pei [1 ]
机构
[1] Univ Teknol Malaysia, Fac Elect Engn, Johor Baharu 81310, Johor, Malaysia
来源
JURNAL TEKNOLOGI | 2014年 / 69卷 / 08期
关键词
Electrical capacitance tomography; segmentation excitation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electrical Capacitance Tomography (ECT) system is a non-intrusive method to detect variation of permittivity distribution in a closed pipe. ECT offers fast response, cheap and non-radiation system. However, it suffers from soft-field effect. One of the proposed solutions to overcome this problem is by applying segmentation excitation, which is to have more than one electrode excited at one time. This paper focuses on various segmentation excitations of 4-electrode combinations using COMSOL Multiphysics software. The electrical potential is recorded at the center of the pipe to study the strength of the electrical potential. The result indicates that 4-electrode adjacent configuration recorded 1.005 x 10(-9)V at the center of the pipe as compared to 0.838 x 10(-9)V for opposite configuration. This effect shows 16.6% difference in electrical potential at the center of the pipe.
引用
收藏
页数:4
相关论文
共 18 条
  • [1] Comparison of different measurement protocols in electrical capacitance tomography using simulations
    Alme, Kjell Joar
    Mylvaganam, Saba
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2119 - 2130
  • [2] Process tomography: A European innovation and its applications
    Beck, MS
    Williams, RA
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) : 215 - 224
  • [3] Dubrofsky E, 2008, LECT NOTES COMPUT SC, V5359, P202, DOI 10.1007/978-3-540-89646-3_20
  • [4] Enhancement of Measurement Efficiency for Electrical Capacitance Tomography
    Fan, Zhaoyan
    Gao, Robert X.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (05) : 1699 - 1708
  • [5] Hendee W R, 1989, Radiographics, V9, P1155
  • [6] Optical sensor configurations for process tomography
    Ibrahim, S
    Green, RG
    Dutton, K
    Evans, K
    Rahim, RA
    Goude, A
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (11) : 1079 - 1086
  • [7] Li Lanying, 2011, 2011 6th International Forum on Strategic Technology (IFOST 2011), P1167, DOI 10.1109/IFOST.2011.6021228
  • [8] A multimodal tomography system based on ECT sensors
    Marashdeh, Qussai
    Warsito, Warsito
    Fan, Liang-Shih
    Teixeira, Fernando L.
    [J]. IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 426 - 433
  • [9] Development of an Electrical Capacitance Tomography system using four rotating electrodes
    Martinez Olmos, A.
    Carvajal, M. A.
    Morales, D. P.
    Garcia, A.
    Palma, A. J.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (02) : 366 - 375
  • [10] Mohamad E. J., 2011, JURNAL TEKNOLOGI, V54, P425