RANDOMIZED TRIAL OF HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION IN RESPIRATORY-DISTRESS SYNDROME

被引:45
作者
CARLO, WA
CHATBURN, RL
MARTIN, RJ
机构
关键词
D O I
10.1016/S0022-3476(87)80173-7
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To compare high-frequenty jet ventilation (HFJV) with pressure-limited time-cycled conventional ventlation (CV), we randomized 41 infants with clinical and radiographic evidence of respiratory distress syndrome during the first day of life to receive either HFJV or CV. Standardized ventilatory protocols were used for 48 hours, after which CV was administered to both groups. Despite comparable oxygenation (arterial/alveolar oxygen tension ratio), mean airway pressure was lower in the HFJV group (9 .+-. 2 vs 13 .+-. 2 cm H2O, P < 0.001), and thus the arterial/alvelar oxygen tension ratio corrected for mean airway pressure was improved in the HFJV group (P < 0.05). PaCO2 was lower during HFJV (37 .+-. 3 vs 42 .+-. 3 mm Hg, P < 0.05) despite a comparable peak inspiratory pressure. The incidence of air leaks, progression of intraventricular hemorrhage, and mortality during the 48-hour period did not differ between the two groups. Bronchoscopies in eight infants given HFJV and five given CV revealed no microscopic evidence of necrotizing tracheobronchitis, but one infant given HFJV had evidence of necrotizing tracheitis at autopsy. We conclude that for 48 hours during the acute stage of respiratory distress syndrome, HFJV can maintain adequate gas exchange at lower mean airway pressure than during CV, without an increase in the incidence of side effects.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 27 条
  • [11] CHATBURN RL, 1983, RESPIR CARE, V28, P1579
  • [12] EDWARDS DK, 1977, PEDIATRICS, V59, P839
  • [13] HIGH AND CONVENTIONAL RATES OF POSITIVE PRESSURE VENTILATION
    FIELD, D
    MILNER, AD
    HOPKIN, IE
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1984, 59 (12) : 1151 - 1154
  • [14] MEAN AIRWAY PRESSURE AND MEAN ALVEOLAR PRESSURE DURING HIGH-FREQUENCY JET VENTILATION IN RABBITS
    FONTAN, JJP
    HELDT, GP
    GREGORY, GA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) : 456 - 463
  • [15] FRANTZ ID, 1983, PEDIATRICS, V71, P483
  • [16] FRANTZ ID, 1985, NEONATAL PEDIATRIC R
  • [17] PROSPECTIVE CLINICAL COMPARISON OF 2 METHODS FOR MECHANICAL VENTILATION OF NEONATES - RAPID RATE AND SHORT INSPIRATORY TIME VERSUS SLOW RATE AND LONG INSPIRATORY TIME
    HEICHER, DA
    KASTING, DS
    HARROD, JR
    [J]. JOURNAL OF PEDIATRICS, 1981, 98 (06) : 957 - 961
  • [18] HEIJMAN K, 1974, OPUSC MED, V19, P235
  • [19] MADANSKY DL, 1979, AM REV RESPIR DIS, V120, P729
  • [20] TREATMENT OF RDS BY HIGH-FREQUENCY OSCILLATORY VENTILATION - A PRELIMINARY-REPORT
    MARCHAK, BE
    THOMPSON, WK
    DUFFTY, P
    MIYAKI, T
    BRYAN, MH
    BRYAN, AC
    FROESE, AB
    [J]. JOURNAL OF PEDIATRICS, 1981, 99 (02) : 287 - 292