PLANAR AND TOMOGRAPHIC IMAGING WITH TECHNETIUM-99M-LABELED TETROFOSMIN - CORRELATION WITH THALLIUM-201 AND CORONARY ANGIOGRAPHY

被引:16
作者
HEO, J
CAVE, V
WASSERLEBEN, V
ISKANDRIAN, AS
机构
[1] Philadelphia Heart Institute, Presbyterian Medical Center, Philadelphia, 19104, PA
关键词
TETROFOSMIN; THALLIUM; 201; SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY; EXERCISE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939953
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared the results of planar and single-photon emission computed tomographic (SPECT) imaging with tetrofosmin with those of Tl-201 and coronary angiography. In three normal volunteers the images were normal by both Tl-201 and tetrofosmin (planar and SPECT). In 23 patients with coronary artery disease, the images were abnormal in 20 patients by SPECT tetrofosmin, in 19 by planar tetrofosmin, in 20 by SPECT thallium, and in 18 by planar thallium (difference not significant). Both planar and SPECT images were divided into five segments per patient. There were 58 perfusion defects by SPECT tetrofosmin, 50 by planar tetrofosmin (difference not significant), 47 by SPECT thallium, and 42 by planar thallium (difference not significant). Perfusion defects were reversible in 47 segments (36%) by SPECT tetrofosmin, 35 (27%) by planar tetrofosmin, 31 (24%) by SPECT thallium (p < 0.05 vs SPECT tetrofosmin), and 31 (24%) by planar thallium (difference not significant). Among the 23 patients with coronary artery disease, 19 underwent coronary angiography. In these patients there were 32 diseased coronary arteries. Perfusion defects were present in 21 territories (66%) by SPECT tetrofosmin, 19 (59%) by planar tetrofosmin, 20 (63%) by SPECT thallium, and 18 (56%) by planar thallium. There was agreement between thallium and tetrofosmin in 108 of 130 segments (kappa statistics = 0.69 +/- 0.06). The images, especially with SPECT, are better with tetrofosmin than with Tl-201. Thus myocardial imaging with tetrofosmin provides results that are at least as good as those of Tl-201. Slightly more abnormal segments and more reversible defects are detected by tetrofosmin than by thallium imaging, especially with SPECT imaging.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 18 条
[1]   PHYSIOLOGICAL-BASIS OF MYOCARDIAL PERFUSION IMAGING WITH THE TECHNETIUM 99M AGENTS [J].
BELLER, GA ;
WATSON, DD .
SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) :173-181
[2]  
BORGESNETO S, 1990, J NUCL MED, V31, P1128
[3]  
DAHLBERG S T, 1992, Journal of Nuclear Medicine, V33, P846
[4]   NEW MYOCARDIAL PERFUSION IMAGING AGENTS - DESCRIPTION AND APPLICATIONS [J].
HEO, J ;
HERMANN, GA ;
ISKANDRIAN, AS ;
ASKENASE, A ;
SEGAL, BL .
AMERICAN HEART JOURNAL, 1988, 115 (05) :1111-1117
[5]  
Heo Jaekyeon, 1993, Journal of the American College of Cardiology, V21, p222A
[6]  
HEO JY, 1992, J NUCL MED, V33, P186
[7]  
HIGLEY B, 1993, J NUCL MED, V34, P30
[8]   EFFECT OF EXERCISE LEVEL ON THE ABILITY OF TL-201 TOMOGRAPHIC IMAGING IN DETECTING CORONARY-ARTERY DISEASE - ANALYSIS OF 461 PATIENTS [J].
ISKANDRIAN, AS ;
HEO, JY ;
KONG, B ;
LYONS, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (06) :1477-1486
[9]   TOMOGRAPHIC MYOCARDIAL PERFUSION IMAGING WITH TC-99M TEBOROXIME DURING ADENOSINE-INDUCED CORONARY HYPEREMIA - CORRELATION WITH TL-201 IMAGING [J].
ISKANDRIAN, AS ;
HEO, J ;
NGUYEN, T ;
BEER, S ;
CAVE, V ;
CASSEL, D ;
ISKANDRIAN, BB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :307-312
[10]   USE OF TECHNETIUM-99M ISONITRILE (RP-30A) IN ASSESSING LEFT-VENTRICULAR PERFUSION AND FUNCTION AT REST AND DURING EXERCISE IN CORONARY-ARTERY DISEASE, AND COMPARISON WITH CORONARY ARTERIOGRAPHY AND EXERCISE TL-201 SPECT IMAGING [J].
ISKANDRIAN, AS ;
HEO, JY ;
KONG, B ;
LYONS, E ;
MARSCH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) :270-275