By utilizing a modified light addressable potentiometric sensor (LAPS) technology, we designed a device for investigation of enzymatic reactions. The sensing principle is the detection of pH variations due to the catalyzed reaction. The system is divided into two main parts, a reaction chamber and a measuring chamber which contains the silicon transducer. By monitoring the H+ production, we obtain information either about the substrate concentration (by using a fixed amount of enzyme) or about the enzyme concentration and activity (if the initial substrate concentrations are constant). Theoretical analysis and modeling were carried out in order to optimize the performance of the system and to predict and explain the experimental curves with alcohol dehydrogenase. By using this set-up it was possible to detect enzyme concentrations down to the 10(-10) M range.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 10 条
[1]   POSSIBLE DEVELOPMENTS OF A POTENTIOMETRIC BIOSENSOR [J].
ADAMI, M ;
SARTORE, M ;
RAPALLO, A ;
NICOLINI, C .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :343-346
[2]   BIOSENSORS FOR DETECTION OF ENZYMES IMMOBILIZED IN MICROVOLUME REACTION CHAMBERS [J].
BOUSSE, L ;
KIRK, G ;
SIGAL, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :555-560
[3]  
BOUSSE L, 1992, CHEM SENSOR TECHNOLO, V4, P145
[4]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[5]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .3. PENICILLIN-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1924-1925
[6]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .2. GLUCOSE-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
PETELENZ, D ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1920-1923
[7]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .1. THEORY [J].
CARAS, SD ;
JANATA, J ;
SAUPE, D ;
SCHMITT, K .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1917-1920
[8]   DETECTION OF SUBNANOGRAM QUANTITIES OF MOJAVE TOXIN VIA ENZYME-IMMUNOASSAY WITH LIGHT ADDRESSABLE POTENTIOMETRIC DETECTOR [J].
COLSTON, JT ;
KUMAR, P ;
RAEL, ED ;
TSIN, ATC ;
VALDES, JJ ;
CHAMBERS, JP .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) :117-121
[9]   LIGHT-ADDRESSABLE POTENTIOMETRIC SENSOR FOR BIOCHEMICAL SYSTEMS [J].
HAFEMAN, DG ;
PARCE, JW ;
MCCONNELL, HM .
SCIENCE, 1988, 240 (4856) :1182-1185
[10]   COMPUTER-SIMULATION AND OPTIMIZATION OF A LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR [J].
SARTORE, M ;
ADAMI, M ;
NICOLINI, C .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (01) :57-64