AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES

被引:70
作者
AMINE, A [1 ]
KAUFFMANN, JM [1 ]
PATRIARCHE, GJ [1 ]
机构
[1] UNIV LIBRE BRUXELLES,INST PHARM,CAMPUS PLAINE,CP 205-6,BD TRIOMPHE,B-1050 BRUSSELS,BELGIUM
关键词
D O I
10.1016/0039-9140(91)80016-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The modification of carbon-paste electrodes by incorporation of the enzyme glucose oxidase (GOD) is described. The resulting probes can be operated as amperometric glucose sensors in the presence or absence of a mediator (1,1'-dimethylferrocene) mixed into the paste. Extended linear calibration ranges have been obtained up to 90 and 50mM glucose respectively. The electrode responses were rapid, reaching steady-state values within 30-40 sec. Advantages of using a GOD-paste formulation are suggested. Plasma glucose assays were correlated with spectrophotometric determinations based on glucose oxidase (y = 1.07x -0.16, r = 0.973, n = 17).
引用
收藏
页码:107 / 110
页数:4
相关论文
共 23 条
[1]  
AMINE A, 1989, ANAL LETT, V22, P2403
[2]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[3]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   ELECTROCHEMICAL-BEHAVIOR OF MARCELLOMYCIN AT LIPID-MODIFIED CARBON-PASTE ELECTRODES [J].
CHASTEL, O ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
CHRISTIAN, GD .
TALANTA, 1990, 37 (02) :213-217
[6]   ULTRAMICRODISK ELECTRODE ENSEMBLES PREPARED BY INCORPORATING CARBON PASTE INTO A MICROPOROUS HOST MEMBRANE [J].
CHENG, IF ;
MARTIN, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2163-2165
[7]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[8]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[9]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[10]  
Guilbault G., 1984, ANAL USES IMMOBILIZE