AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION

被引:164
作者
CHI, QJ [1 ]
DONG, SJ [1 ]
机构
[1] CHINESE ACAD SCI, CHANGCHUN INST APPL CHEM, ELECTROANALYT CHEM LAB, CHANGCHUN 130022, PEOPLES R CHINA
关键词
BIOSENSORS; AMPEROMETRY; PRUSSIAN BLUE; GLUCOSE OXIDASE; AMINO OXIDASE;
D O I
10.1016/0003-2670(95)00152-P
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Prussian blue has been formed by cyclic voltammetry onto the basal pyrolytic graphite surface to prepare a chemically modified electrode which provides excellent electrocatalysis for both oxidation and reduction of hydrogen peroxide. It is found for the first time that glucose oxidase or D-amino oxidase can be incorporated into a Prussian blue film during its electrochemical growth process. Two amperometric biosensors were fabricated by electrochemical codeposition, and the resulting sensors were protected by coverage with a thin film of Nafion. The influence of various experimental conditions was examined for optimum analytical performance. The glucose sensor responds rapidly to substrates with a detection limit of 2 x 10(-6) M and a linear concentration range of 0.01-3 mM. There was no interference from 2 mM ascorbic acid or uric acid. Another (D-amino acid) sensor gave a detection limit of 3 x 10(-5) M D-alanine, injected with a linear concentration range of 7.0 x 10(-5)-1.4 x 10(-2) M. Glucose and D-amino acid sensors remain relatively stable for 20 and 15 days, respectively. There is no obvious interference from anion electroactive species due to a low operating potential and excellent permselectivity of Nafion.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 33 条
[1]   STRATEGIES FOR THE DEVELOPMENT OF AMPEROMETRIC ENZYME ELECTRODES [J].
BARTLETT, PN ;
WHITAKER, RG .
BIOSENSORS, 1988, 3 (06) :359-379
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[3]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[4]   ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM [J].
COOPER, JC ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :473-485
[5]   ELECTROCHROMISM IN THE MIXED-VALENCE HEXACYANIDES .1. VOLTAMMETRIC AND SPECTRAL STUDIES OF THE OXIDATION AND REDUCTION OF THIN-FILMS OF PRUSSIAN BLUE [J].
ELLIS, D ;
ECKHOFF, M ;
NEFF, VD .
JOURNAL OF PHYSICAL CHEMISTRY, 1981, 85 (09) :1225-1231
[6]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[7]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[8]  
FREW JE, 1986, J CHEM TECHNOL BIOT, V36, P357
[9]   CLAY-MODIFIED ELECTRODES [J].
GHOSH, PK ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (17) :5691-5693
[10]   ELECTROCHEMICAL FABRICATION OF AMPEROMETRIC MICROENZYME SENSOR [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
YUKIASHI, T ;
USHIODA, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (03) :702-706