Remote Monitoring for Implantable Defibrillators: A Nationwide Survey in Italy

被引:9
|
作者
Luzi, Mario [1 ]
De Simone, Antonio [2 ]
Leoni, Loira [3 ]
Amellone, Claudia [4 ]
Pisano, Ennio [5 ]
Favale, Stefano [6 ]
Iacoviello, Massimo [6 ]
Luise, Raffaele [7 ]
Bongiorni, Maria Grazia [8 ]
Stabile, Giuseppe [9 ]
La Rocca, Vincenzo [2 ]
Folino, Franco [3 ]
Capucci, Alessandro [1 ]
D'Onofrio, Antonio [10 ]
Accardi, Francesco [11 ]
Valsecchi, Sergio [11 ]
Buia, Gianfranco [3 ]
机构
[1] Univ Ospedali Riuniti, Azienda Osped, Cardiol Clin, Via Conca,71, I-60126 Ancona, Italy
[2] Clin San Michele, Maddaloni, Italy
[3] Univ Padua, Azienda Osped, Padua, Italy
[4] Osped Civile Cirie, Cirie, Italy
[5] Vito Fazzi Hosp, Lecce, Italy
[6] Univ Bari, Bari, Italy
[7] Osped San Salvatore, Coppito, Italy
[8] Univ Hosp Pisa, Pisa, Italy
[9] Clin Mediterranea, Naples, Italy
[10] Azienda Osped Colli Monaldi, Naples, Italy
[11] Boston Sci, Milan, Italy
来源
INTERACTIVE JOURNAL OF MEDICAL RESEARCH | 2013年 / 2卷 / 02期
关键词
implantable defibrillator; remote monitoring; follow-up;
D O I
10.2196/ijmr.2824
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Remote monitoring (RM) permits home interrogation of implantable cardioverter defibrillator (ICD) and provides an alternative option to frequent in-person visits. Objective: The Italia-RM survey aimed to investigate the current practice of ICD follow-up in Italy and to evaluate the adoption and routine use of RM. Methods: An ad hoc questionnaire on RM adoption and resource use during in-clinic and remote follow-up sessions was completed in 206 Italian implanting centers. Results: The frequency of routine in-clinic ICD visits was 2 per year in 158/206 (76.7%) centers, 3 per year in 37/206 (18.0%) centers, and 4 per year in 10/206 (4.9%) centers. Follow-up examinations were performed by a cardiologist in 203/206 (98.5%) centers, and by more than one health care worker in 184/206 (89.3%) centers. There were 137/206 (66.5%) responding centers that had already adopted an RM system, the proportion of ICD patients remotely monitored being 15% for single-and dual-chamber ICD and 20% for cardiac resynchronization therapy ICD. Remote ICD interrogations were scheduled every 3 months, and were performed by a cardiologist in 124/137 (90.5%) centers. After the adoption of RM, the mean time between in-clinic visits increased from 5 (SD 1) to 8 (SD 3) months (P<.001). Conclusions: In current clinical practice, in-clinic ICD follow-up visits consume a large amount of health care resources. The results of this survey show that RM has only partially been adopted in Italy and, although many centers have begun to implement RM in their clinical practice, the majority of their patients continue to be routinely followed-up by means of in-clinic visits.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 50 条
  • [41] Alert-driven vs scheduled remote monitoring of implantable cardiac defibrillators: A cost- consequence analysis from the TRUST trial
    Chew, Derek S.
    Piccini, Jonathan P.
    Au, Flora
    Frazier-Mills, Camille G.
    Michalski, Justin
    Varma, Niraj
    TRUST Investigators
    HEART RHYTHM, 2023, 20 (03) : 440 - 447
  • [42] Reduction in long-term mortality using remote device monitoring in a large real-world population of patients with implantable defibrillators
    Kolk, Maarten Z. H.
    Narayan, Sanjiv M.
    Clopton, Paul
    Wilde, Arthur A. M.
    Knops, Reinoud E.
    Tjong, Fleur V. Y.
    EUROPACE, 2023, 25 (03): : 969 - 977
  • [43] Implantable cardioverter defibrillators and devices for cardiac resynchronization therapy: what perspective for patients' apps combined with remote monitoring?
    Sgreccia, Daria
    Mauro, Erminio
    Vitolo, Marco
    Manicardi, Marcella
    Valenti, Anna Chiara
    Imberti, Jacopo Francesco
    Ziacchi, Matteo
    Boriani, Giuseppe
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (02) : 155 - 160
  • [44] Addition of Blood Pressure and Weight Transmissions to Standard Remote Monitoring of Implantable Defibrillators and its Association with Mortality and Rehospitalization
    Al-Chekakie, M. Obadah
    Bao, Haikun
    Jones, Paul W.
    Stein, Kenneth M.
    Marzec, Lucas
    Varosy, Paul D.
    Masoudi, Frederick A.
    Curtis, Jeptha P.
    Akar, Joseph G.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2017, 10 (05):
  • [45] Remote monitoring to Improve long-term prognosis in heart failure patients with implantable cardioverter-defibrillators
    Ono, Maki
    Varma, Niraj
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (05) : 335 - 342
  • [46] Impact of COVID-19 Pandemic on Remote Monitoring of Cardiac Implantable Electronic Devices in Italy: Results of a Survey Promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
    Maines, Massimiliano
    Palmisano, Pietro
    Del Greco, Maurizio
    Melissano, Donato
    De Bonis, Silvana
    Baccillieri, Stella
    Zanotto, Gabriele
    D'Onofrio, Antonio
    Ricci, Renato Pietro
    De Ponti, Roberto
    Boriani, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [47] Remote monitoring of cardiac implantable electronic devices (CIED)
    Zeitler, Emily P.
    Piccini, Jonathan P.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2016, 26 (06) : 568 - 577
  • [48] The patient perspective on remote monitoring of implantable cardiac devices
    Hillmann, Henrike A. K.
    Hansen, Claudius
    Przibille, Oliver
    Duncker, David
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [49] Remote monitoring of pacemakers and implantable cardioverter-defibrillators, safety aspects and study in cardiac implant patients on EMF exposure
    Plawiak-Mowna, Anna
    Krawczyk, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (12B): : 137 - 140
  • [50] Economic impact of remote monitoring after implantable defibrillators implantation in heart failure patients: an analysis from the EFFECT study
    Capucci, Alessandro
    De Simone, Antonio
    Luzi, Mario
    Calvi, Valeria
    Stabile, Giuseppe
    D'Onofrio, Antonio
    Maffei, Simone
    Leoni, Loira
    Morani, Giovanni
    Sangiuolo, Raffaele
    Amellone, Claudia
    Checchinato, Catia
    Ammendola, Ernesto
    Buja, Gianfranco
    EUROPACE, 2017, 19 (09): : 1493 - 1499