MEASUREMENT OF KINETIC ENERGIES OF IONS EJECTED FROM A QUADRUPOLE ION TRAP

被引:17
|
作者
REISER, HP [1 ]
KAISER, RE [1 ]
SAVICKAS, PJ [1 ]
COOKS, RG [1 ]
机构
[1] DOW CHEM CO USA,ANALYT LABS,MIDLAND,MI 48674
关键词
D O I
10.1016/0168-1176(91)85021-D
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Kinetic energies of ions of different mass-to-charge ratios exiting a Paul-type ion trap, operated in the mass-selective instability mode, are measured by a retarding potential method. Average kinetic energies increase with mass, a typical value being 2900 eV with a distribution of 900 eV (FWHM) for m/z 502, C9F20N+. The maximum value remains in the same range but the width of the distribution increases when the trap is operated at lower He bath gas pressure. When ion ejection is performed at reduced values of the Mathieu parameter beta-z, the most probable ion kinetic energy decreases, following the amplitude of the main r.f. voltage. For example, m/z 502 when resonantly ejected at beta-z 0.48 shows a maximum kinetic energy of only 644 eV. Simulations of ion motion employing stepwise integration yield values of the maximum kinetic energies which are in good agreement with the experimental data. The implications of these results for the mass resolution of the ion trap and for other performance data are discussed.
引用
收藏
页码:237 / 247
页数:11
相关论文
共 50 条
  • [31] Ion-molecule reactions of benzoyl ions in a quadrupole ion trap mass spectrometer
    Creaser, CS
    Wiliamson, BL
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1996, (03): : 427 - 433
  • [32] A simulation study of ion kinetic energies during resonant excitation in a stretched ion trap
    Splendore, M
    Londry, FA
    March, RE
    Morrison, RJS
    Perrier, P
    Andre, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 156 (1-2): : 11 - 29
  • [33] Comparison between the energies of ejected ions in the cases of KrF laser ablation and Ar ion sputtering
    Ohwaki, T
    Akihama, K
    Taga, Y
    Takayanagi, N
    Taki, M
    APPLIED SURFACE SCIENCE, 1997, 113 : 773 - 776
  • [34] Characterization of protonated phospholipids as fragile ions in quadrupole ion trap mass spectrometry
    Garrett, Timothy J.
    Merves, Matthew
    Yost, Richard A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 308 (2-3) : 299 - 304
  • [35] CONFINEMENT OF PULSE-INJECTED EXTERNAL IONS IN A RADIOFREQUENCY QUADRUPOLE ION TRAP
    O, CS
    SCHUESSLER, HA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 40 (01): : 53 - 66
  • [36] Substitution reactions of gaseous ions in a three-dimensional quadrupole ion trap
    Parchomyk, Tobias
    Koszinowski, Konrad
    JOURNAL OF MASS SPECTROMETRY, 2019, 54 (01): : 81 - 87
  • [37] Origin of product ions in the MS/MS spectra of peptides in a quadrupole ion trap
    Vachet, RW
    Ray, KL
    Glish, GL
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) : 341 - 344
  • [38] Kinetics of solvent addition on electrosprayed ions in an electrospray source and in a quadrupole ion trap
    Gabelica, V
    Lemaire, D
    Laprévote, O
    De Pauw, E
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 210 (1-3) : 113 - 119
  • [39] The Effective Temperature of Ions Stored in a Linear Quadrupole Ion Trap Mass Spectrometer
    Donald, William A.
    Khairallah, George N.
    O'Hair, Richard A. J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (06) : 811 - 815
  • [40] Ejection process of photofragment ions from a quadrupole ion trap (vol 337, pg 12, 2013)
    Choi, Chang Min
    Heo, Jiyoung
    Choi, Myoung Choul
    Kim, Nam Joon
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 362 : 39 - 39