PERFORMANCE OF A MEDICAL X-RAY IMAGE INTENSIFIER OPTICALLY COUPLED TO A COOLED CCD CAMERA

被引:0
|
作者
MOY, JP
MORSE, J
机构
来源
INSTITUTE OF PHYSICS CONFERENCE SERIES | 1992年 / 121期
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A standard medical X-ray Image Intensifier (XRII) has been coupled by relay lenses to a cooled 1024 x 1024 CCD camera. This combination allows single X photon detection down to almost-equal-to 20 keV, with a spatial resolution of up to 500 line pairs across the empty set 220 mm sensitive area. Sensitivity will be extended down to 5 keV by the use of a Be window to meet the requirements of X-ray biological diffraction experiments with synchrotron radiation.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 50 条
  • [1] The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector
    Fujisawa, T
    Inoko, Y
    Yagi, N
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1106 - 1114
  • [2] INTRAORAL X-RAY FLUOROSCOPY WITH IMAGE INTENSIFIER AND CCD
    BOUCHIER, G
    LEDENMAT, D
    CAMUS, JP
    ROVILLE, JC
    MARTIN, G
    RICHARD, JC
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 558 - 558
  • [3] Study on gamma-ray imaging with an image-intensifier and a cooled CCD camera
    Saitoh, N
    Kuroki, K
    Kurosawa, K
    Akiba, N
    ENABLING TECHNOLOGIES FOR LAW ENFORCEMENT AND SECURITY, 2000, 4232 : 497 - 504
  • [4] X-ray image intensifier
    Balter, S
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 46 (02) : 238 - 244
  • [5] X-RAY IMAGE INTENSIFIER
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1954, 2 (4895): : 1044 - 1044
  • [6] X-RAY IMAGE INTENSIFIER
    MCDONALD, RE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 691 - 691
  • [7] USE OF A MEDICAL X-RAY IMAGE INTENSIFIER IN LAUE INVESTIGATIONS
    FUCHS, EG
    VARGA, L
    ACTA TECHNICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1971, 70 (1-2): : 191 - &
  • [8] Electric-field-induced structural changes measured with a CCD-coupled X-ray image intensifier
    van Reeuwijk, SJ
    Vonk, V
    Puig-Molina, A
    Graafsma, H
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 : 1422 - 1429
  • [9] 35 MM CINE CAMERA INCORPORATING A PHILIPS X-RAY IMAGE INTENSIFIER
    ARDRAN, GM
    WYATT, DG
    JOURNAL OF PHYSIOLOGY-LONDON, 1954, 126 (03): : P1 - P2
  • [10] A 200 MM INPUT FIELD, 5-80 KEV DETECTOR BASED ON AN X-RAY IMAGE INTENSIFIER AND CCD CAMERA
    MOY, JP