ACCURACY OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENTS IN HYPERTENSIVE AND OBESE SUBJECTS

被引:33
作者
NIELSEN, PE
LARSEN, B
HOLSTEIN, P
POULSEN, HL
机构
[1] HVIDOVRE HOSP, DEPT INTERNAL MED, DIV CARDIOL, DK-2650 HVIDOVRE, DENMARK
[2] UNIV COPENHAGEN, BISPEBJERG HOSP, DEPT CLIN PHYSIOL, COPENHAGEN, DENMARK
关键词
D O I
10.1161/01.HYP.5.1.122
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
引用
收藏
页码:122 / 127
页数:6
相关论文
共 18 条
[1]  
BURTON AC, 1962, HDB PHYSL
[2]  
Donde R, 1974, Ugeskr Laeger, V136, P1431
[3]  
FORSBERG SA, 1970, ACTA MED SCAND, V188, P389
[4]   THE CHANGES IN THE INTRA-ARTERIAL PRESSURE DURING IMMERSION OF THE HAND IN ICE-COLD WATER [J].
GODDEN, JO ;
ROTH, GM ;
HINES, EA ;
SCHLEGEL, JF .
CIRCULATION, 1955, 12 (06) :963-973
[5]   SIMULTANEOUS DIRECT AND INDIRECT BLOOD PRESSURE MEASUREMENTS IN MAN AT REST AND WORK [J].
HENSCHEL, A ;
DELAVEGA, F ;
TAYLOR, HL .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 6 (08) :506-508
[6]   MEASUREMENT OF BLOOD-PRESSURE - COMPARISON OF INTRA-ARTERIAL + CUFF VALUES [J].
HOLLAND, WW ;
HUMERFELT, S .
BRITISH MEDICAL JOURNAL, 1964, 2 (541) :1241-&
[7]  
IMHOF P, 1958, Cardiologia, V33, P2, DOI 10.1159/000166315
[8]   SPHYGMOMANOMETER CUFF SIZE + ACCURACY OF INDIRECT MEASUREMENT OF BLOOD PRESSURE [J].
KARVONEN, MJ ;
TELIVUO, LJ ;
JARVINEN, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1964, 13 (05) :688-&
[9]  
KING GE, 1967, CLIN SCI, V32, P223
[10]   RECOMMENDATIONS FOR HUMAN BLOOD PRESSURE DETERMINATION BY SPHYGMOMANOMETERS [J].
KIRKENDALL, WM ;
BURTON, AC ;
EPSTEIN, FH ;
FREIS, ED .
CIRCULATION, 1967, 36 (06) :980-+