Measurement of time delay for a prospectively gated CT simulator

被引:5
|
作者
Goharian, M. [1 ]
Khan, R. F. H. [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
[2] Univ Calgary, Dept Oncol Phys & Astron, Calgary, AB, Canada
关键词
CT simulator; prospective gating; time delay;
D O I
10.4103/0971-6203.62196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patients breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) X-Ray ON status signal from the CT scanner in a text file. The TTL X-Ray ON indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery; otherwise the simulation and treatment may not be correlated with the patients breathing.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [31] MICROPROCESSOR-BASED SIMULATOR OF A VARIABLE TIME-DELAY
    STAJIC, D
    MICROPROCESSORS AND MICROSYSTEMS, 1982, 6 (02) : 73 - 75
  • [32] Time delay interferometry using the UF LISA benchtop simulator
    Cruz, Rachel J.
    Thorpe, James I.
    Hartman, Michael
    Mueller, Guido
    LASER INTERFEROMETER SPACE ANTENNA, 2006, 873 : 319 - +
  • [33] Diagnostic accuracy of prospectively ECG Gated axial scans; a radiation dose reduction method for Coronary CT Angiography
    Chihara, R.
    Sano, K.
    Yamasaki, T.
    Kimura, F.
    Nishimura, S.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S82 - S82
  • [34] Time delay measurement in the frequency domain
    Durbin, Stephen M.
    Liu, Shih-Chieh
    Dufresne, Eric M.
    Li, Yuelin
    Wen, Haidan
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1293 - 1296
  • [35] Measurement of the delay time of pulse sequence
    Popov D.I.
    Radioelectronics and Communications Systems, 2013, 56 (7) : 356 - 364
  • [36] PROSPECTIVELY GATED CARDIAC CT - PRELIMINARY-RESULTS IN NORMAL AND POST-INFARCTION ANIMAL-MODELS
    GARNIC, JD
    MOORE, SC
    JUDY, PF
    HARRINGTON, DP
    LOIS, J
    LEVIN, DC
    INVESTIGATIVE RADIOLOGY, 1983, 18 (05) : 419 - 424
  • [37] Prospectively Gated CBCT for Volumetric Image Guidance in SBRT
    Fahimian, B. P.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S199 - S200
  • [38] A new approach for prospectively gated cardiac rotational angiography
    De Buck, Stijn
    Dauwe, Dieter
    Wielandts, Jean-Yves
    Claus, Piet
    Janssens, Stefan
    Heidbuchel, Hein
    Nuyens, Dieter
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [39] Evaluation of image noise in prospectively respiratory gated PET
    Detorie, Nicole C.
    Kesner, Adam L.
    Solberg, Timothy D.
    Dahlbom, Magnus
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2566 - 2570
  • [40] Measurement of imaging and treatment time delays in gated radiotherapy
    Smith, W.
    Becker, N.
    MEDICAL PHYSICS, 2009, 36 (09) : 4307 - 4308