Measurement of time delay for a prospectively gated CT simulator

被引:5
|
作者
Goharian, M. [1 ]
Khan, R. F. H. [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
[2] Univ Calgary, Dept Oncol Phys & Astron, Calgary, AB, Canada
关键词
CT simulator; prospective gating; time delay;
D O I
10.4103/0971-6203.62196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patients breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) X-Ray ON status signal from the CT scanner in a text file. The TTL X-Ray ON indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery; otherwise the simulation and treatment may not be correlated with the patients breathing.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [21] A digital simulation technique for time delay in wide area measurement system and its realization in real-time digital simulator
    Zhang, Fang
    Cheng, Lin
    Li, Xiong
    Chen, Gang
    Sun, Yuanzhang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (17): : 99 - 105
  • [22] PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY
    MOORE, SC
    JUDY, PF
    GARNIC, JD
    KAMBIC, GX
    BONK, F
    COCHRAN, G
    MARGOSIAN, P
    MCCROSKEY, W
    FOOTE, F
    MEDICAL PHYSICS, 1983, 10 (06) : 846 - 855
  • [23] Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    Earls, James P.
    Berman, Elise L.
    Urban, Bruce A.
    Curry, Charlene A.
    Lane, Judith L.
    Jennings, Robert S.
    McCulloch, Colin C.
    Hsieh, Jiang
    Londt, John H.
    RADIOLOGY, 2008, 246 (03) : 742 - 753
  • [24] MEASUREMENT OF GROUP TIME-DELAY AND CHECKING OF GROUP TIME-DELAY MEASUREMENT DEVICES
    SOKOV, IA
    SEMENOVA, VP
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (09): : 1387 - &
  • [25] PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY
    MOORE, SC
    JUDY, PF
    GARNIC, JD
    KAMBIC, GX
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (02) : 351 - 352
  • [26] Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT
    Simon-Yarza, Isabel
    Viteri-Ramirez, Guillermo
    Saiz-Mendiguren, Ramon
    Slon-Roblero, Pedro J.
    Paramo, Maria
    Bastarrika, Gorka
    ACTA RADIOLOGICA, 2012, 53 (05) : 536 - 540
  • [27] Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique
    Oliver Klass
    Martin Jeltsch
    Sebastian Feuerlein
    Horst Brunner
    Hans-Dieter Nagel
    Matthew J. Walker
    Hans-Juergen Brambs
    Martin H. K. Hoffmann
    European Radiology, 2009, 19 : 829 - 836
  • [28] Feasibility of prospectively electrocardiogram-gated low-dose coronary CT angiography in a large population
    Buechel, R.
    Herzog, B.
    Husmann, L.
    Burger, I.
    Pazhenkottil, A.
    Gaemperli, O.
    Valenta, I.
    Treyer, V.
    Wyss, C.
    Kaufmann, P.
    EUROPEAN HEART JOURNAL, 2009, 30 : 749 - 749
  • [29] Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique
    Klass, Oliver
    Jeltsch, Martin
    Feuerlein, Sebastian
    Brunner, Horst
    Nagel, Hans-Dieter
    Walker, Matthew J.
    Brambs, Hans-Juergen
    Hoffmann, Martin H. K.
    EUROPEAN RADIOLOGY, 2009, 19 (04) : 829 - 836
  • [30] Time-delay measurement of phase gated treatment with a varian real-time position management system using computed radiography
    Hanna, G.
    Wang, Z.
    Yin, F.
    MEDICAL PHYSICS, 2007, 34 (06) : 2498 - 2498