Measurement of time delay for a prospectively gated CT simulator

被引:5
|
作者
Goharian, M. [1 ]
Khan, R. F. H. [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
[2] Univ Calgary, Dept Oncol Phys & Astron, Calgary, AB, Canada
关键词
CT simulator; prospective gating; time delay;
D O I
10.4103/0971-6203.62196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patients breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) X-Ray ON status signal from the CT scanner in a text file. The TTL X-Ray ON indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery; otherwise the simulation and treatment may not be correlated with the patients breathing.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [1] Time delay study of a CT simulator in respiratory gated CT scanning
    Guan, H.
    MEDICAL PHYSICS, 2006, 33 (06) : 2145 - 2145
  • [2] Time delay study of a CT simulator in respiratory gated CT scanning
    Guan, HQ
    MEDICAL PHYSICS, 2006, 33 (04) : 815 - 819
  • [3] Prospectively gated cardiac CT
    Heuscher, Dominic
    Zabic, Stanislav
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2621 - 2623
  • [4] QUALITATIVE AND QUANTITATIVE-EVALUATION OF PROSPECTIVELY GATED CARDIAC CT
    GARNIC, JD
    MOORE, SC
    JUDY, PF
    LEVIN, DC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (02) : 357 - 358
  • [5] Optimal Cardiac Phase in Prospectively Gated Axial Cardiac CT Scans
    Zamyatin, Alexander
    Karbeyaz, Basak Ulker
    Shaughnessy, Charlie
    Rozas, David
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [6] Delay Time Compensation for a Hybrid Simulator
    Osaki, Kohei
    Konno, Atsushi
    Uchiyama, Masaru
    ADVANCED ROBOTICS, 2010, 24 (8-9) : 1081 - 1098
  • [7] An affordable custom phantom for measurement of linac time delay in gated treatments with irregular breathing
    Santos, Alexandre M. Caraca
    Shepherd, Justin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (03) : 863 - 869
  • [8] An affordable custom phantom for measurement of linac time delay in gated treatments with irregular breathing
    Alexandre M. Caraça Santos
    Justin Shepherd
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 863 - 869
  • [9] Dose and image quality comparison between prospectively gated axial and retrospectively gated helical coronary CT angiography
    Hlaihel, C.
    Boussel, L.
    Cochet, H.
    Roch, J. A.
    Coulon, P.
    Walker, M. J.
    Douek, P. C.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 51 - 57
  • [10] CT IMAGING OF MYOCARDIAL INFARCT SIZE AND FUNCTION AFTER CORONARY-OCCLUSION WITH PROSPECTIVELY GATED CT
    SLUTSKY, RA
    MATTREY, RF
    LONG, SA
    HIGGINS, CB
    CIRCULATION, 1982, 66 (04) : 41 - 41