Improved centration of the type I Boston Keratoprosthesis in donor carrier tissue

被引:9
|
作者
Khalifa, Yousuf M. [1 ]
Moshirfar, Majid [2 ]
机构
[1] Univ Rochester, Flaum Eye Inst, Rochester, NY USA
[2] Univ Utah, Moran Eye Ctr, Salt Lake City, UT USA
来源
CLINICAL OPHTHALMOLOGY | 2010年 / 4卷
关键词
Boston Keratoprosthesis; centration error;
D O I
10.2147/OPTH.S12778
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error.
引用
收藏
页码:931 / 933
页数:3
相关论文
共 48 条
  • [31] Bilateral Boston keratoprosthesis type 1 in a case of severe Mooren's ulcer
    Jerez-Pena, Marta
    Salvador-Culla, Borja
    de la Paz, Maria F.
    Barraquer, Rafael, I
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : NP33 - NP38
  • [32] Wide-field vitreoretinal surgery in eyes with Boston type 1 keratoprosthesis
    Canan Asli Utine
    Mahmut Kaya
    Kıvanç Kasal
    International Ophthalmology, 2022, 42 : 997 - 1005
  • [33] Eight-years Egyptian experience of Boston type I keratoprosthesis following failed penetrating keratoplasty or ocular surface disease
    Othman, Ihab S.
    Gharieb, Hesham M.
    Ibrahim, Hani M. G.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2022, 36 (01) : 102 - 106
  • [34] Sequential versus concomitant surgery of glaucoma drainage implant and Boston keratoprosthesis type 1
    Patel, Varun
    Moster, Marlene R.
    Kishfy, Louis
    Barkan, Julian
    Zhan, Tingting
    Raber, Irving M.
    Ayres, Brandon D.
    Pro, Michael J.
    Waisbourd, Michael
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : 556 - 563
  • [35] Boston type 1 keratoprosthesis for severe blinding vernal keratoconjunctivitis and Mooren's ulcer
    Basu S.
    Taneja M.
    Sangwan V.S.
    International Ophthalmology, 2011, 31 (3) : 219 - 222
  • [36] Medium-term Outcomes of Boston Type 1 Keratoprosthesis Implantation in Bangkok, Thailand
    Lekhanont, Kaevalin
    Thaweesit, Panyachat
    Muntham, Dittapol
    Chuckpaiwong, Varintorn
    Vongthongsri, Anun
    CORNEA, 2014, 33 (12) : 1312 - 1319
  • [37] Schiotz Tonometry Accurately Measures Intraocular Pressure in Boston Type 1 Keratoprosthesis Eyes
    Estrovich, Igor E.
    Shen, Chris
    Chu, Yvonne
    Downs, J. Crawford
    Gardiner, Stuart
    Straiko, Michael
    Mansberger, Steven L.
    CORNEA, 2015, 34 (06) : 682 - 685
  • [38] Intermediate-Term and Long-Term Outcomes With the Boston Type 1 Keratoprosthesis in Aniridia
    Shah, Kevin J.
    Cheung, Albert Y.
    Holland, Edward J.
    CORNEA, 2018, 37 (01) : 11 - 14
  • [39] INTRAOPERATIVE OCULAR MANOMETRY IN SILICONE OIL-FILLED EYES WITH A BOSTON TYPE 1 KERATOPROSTHESIS
    Toygar, Okan
    Mestanoglu, Mert
    Riemann, Christopher D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (11): : 2155 - 2160
  • [40] Tear Film Cytokine Profile of Patients With the Boston Keratoprosthesis Type 1: Comparing Patients With and Without Glaucoma
    Geoffrion, Dominique
    Robert, Marie-Claude
    Di Polo, Adriana
    Koenekoop, Robert K.
    Agoumi, Younes
    Harissi-Dagher, Mona
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (04)