Improved centration of the type I Boston Keratoprosthesis in donor carrier tissue

被引:9
|
作者
Khalifa, Yousuf M. [1 ]
Moshirfar, Majid [2 ]
机构
[1] Univ Rochester, Flaum Eye Inst, Rochester, NY USA
[2] Univ Utah, Moran Eye Ctr, Salt Lake City, UT USA
来源
CLINICAL OPHTHALMOLOGY | 2010年 / 4卷
关键词
Boston Keratoprosthesis; centration error;
D O I
10.2147/OPTH.S12778
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error.
引用
收藏
页码:931 / 933
页数:3
相关论文
共 50 条
  • [1] Improving Boston type 1 keratoprosthesis procedure: one-touch femtosecond-assisted preparation and centration of donor carrier tissue
    Malandrini, Alex
    Balestrazzi, Angelo
    Canovetti, Annalisa
    Rossi, Francesca
    Cortesini, Letizia
    Lenzetti, Chiara
    Pini, Roberto
    Menabuoni, Luca
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (02) : 191 - 195
  • [2] Boston type I keratoprosthesis
    Hu, Karen
    Tarib, Imane
    Cortina, Maria Soledad
    ANNALS OF EYE SCIENCE, 2024, 9
  • [3] Femtosecond-assisted preparation of donor tissue for Boston type 1 keratoprosthesis
    Moshirfar, Majid
    Neuffer, Marcus C.
    Kinard, Krista
    Lependu, Monette T.
    Sikder, Shameema
    CLINICAL OPHTHALMOLOGY, 2011, 5 : 1017 - 1020
  • [4] Boston keratoprosthesis type I in the elderly
    Homayounfar, Gelareh
    Grassi, Christina M.
    Al-Moujahed, Ahmad
    Colby, Kathryn A.
    Dohlman, Claes H.
    Chodosh, James
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 514 - 518
  • [5] Glaucoma Associated With Boston Type I Keratoprosthesis
    Kamyar, Roheena
    Weizer, Jennifer S.
    de Paula, Fernando Heitor
    Stein, Joshua D.
    Moroi, Sayoko E.
    John, Denise
    Musch, David C.
    Mian, Shahzad I.
    CORNEA, 2012, 31 (02) : 134 - 139
  • [6] Treatment of Aniridia With Boston Type I Keratoprosthesis
    Rixen, Jordan J.
    Cohen, Alex W.
    Kitzmann, Anna S.
    Wagoner, Michael D.
    Goins, Kenneth M.
    CORNEA, 2013, 32 (07) : 947 - 950
  • [7] Boston type I keratoprosthesis. Review
    Kwitko, Sergio
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (06) : 447 - 447
  • [8] Boston type I keratoprosthesis. Review
    Magalhaes, Fernanda Pedreira
    de Sousa, Luciene Barbosa
    De Oliveira, Lauro Augusto
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 218 - 222
  • [9] Visual outcomes in the Boston keratoprosthesis type I
    Ma, JJK
    Barnes, S
    Dohlman, CH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U481 - U481
  • [10] International Results with the Boston Type I Keratoprosthesis
    Aldave, Anthony J.
    Sangwan, Virender S.
    Basu, Sayan
    Basak, Samar K.
    Hovakimyan, Anna
    Gevorgyan, Ofelya
    Al Kharashi, Soliman
    Al Jindan, Mohanna
    Tandon, Radhika
    Mascarenhas, Jeena
    Malyugin, Boris
    Padilla, Ma Dominga B.
    Maskati, Quresh
    Agarwala, Nisheeta
    Hutauruk, Johan
    Sharma, Manoj
    Yu, Fei
    OPHTHALMOLOGY, 2012, 119 (08) : 1530 - 1538