SENSITIZATION OF POLYMERIC TRACK DETECTORS WITH CARBON-DIOXIDE

被引:17
|
作者
FUJII, M
YOKOTA, R
KOBAYASHI, T
HASEGAWA, H
机构
[1] INST SPACE & ASTRONAUT SCI,SAGAMIHARA,KANAGAWA 229,JAPAN
[2] AOYAMA GAKUIN UNIV,SETAGAYA KU,TOKYO 157,JAPAN
[3] FUKUVI CHEM IND CO LTD,FUKUI 91905,JAPAN
关键词
SR-90; CR-39; POLYMER; TRACK DETECTOR; HIGH SENSITIVITY; AGING; CARBON DIOXIDE;
D O I
10.1016/1350-4487(95)00056-K
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The effect of CO2 on the sensitivity of polymeric track detectors was studied, It has been found that the sensitivity of SR-90 is dependent on the amount of CO2 dissolved in the polymer at the time of etching. It has been also found that CR-39 can be sensitized to some extent with an aging in CO2. Since the sensitization in CO2 is possible even a long time after the irradiation, the mechanism of the latent track formation by CO2 is quite different from that by O-2. This would be the key to achieve the long term stability of polymeric track detectors such as SR-90 and CR-39.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [1] On the mechanism of the sensitization of PADC (poly(allyl diglycol carbonate)) track detectors by carbon dioxide treatment
    Hassan, Nabil M.
    Matai, Yuri
    Kusumoto, Tamon
    Mori, Yutaka
    Kanasaki, Masato
    Oda, Keiji
    Kitamura, Hisashi
    Konishi, Teruaki
    Kodaira, Satoshi
    Yasuda, Nakahiro
    Yamauchi, Tomoya
    RADIATION MEASUREMENTS, 2013, 59 : 23 - 29
  • [2] Sensitization of PADC track detector in carbon dioxide gas
    Yamauchi, Tomoya
    Mori, Yutaka
    Chikada, Hiraku
    Sakamoto, Atsushi
    Kii, Junpei
    Kanasaki, Masato
    Oda, Keiji
    Fujii, Masami
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 1105 - 1108
  • [3] POLYMERIC MICROSPHERES PREPARED BY SPRAYING INTO COMPRESSED CARBON-DIOXIDE
    BODMEIER, R
    WANG, H
    DIXON, DJ
    MAWSON, S
    JOHNSTON, KP
    PHARMACEUTICAL RESEARCH, 1995, 12 (08) : 1211 - 1217
  • [4] Post-irradiation sensitization of CR-39 track detector in carbon dioxide atmosphere
    Csige, I
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 171 - 176
  • [5] CARBON-DIOXIDE ABSORPTION IS NOT LINEARLY RELATED TO INTRAPERITONEAL CARBON-DIOXIDE INSUFFLATION PRESSURE IN PIGS
    LISTER, DR
    RUDSTONBROWN, B
    WARRINER, CB
    MCEWEN, J
    CHAN, M
    WALLEY, KR
    ANESTHESIOLOGY, 1994, 80 (01) : 129 - 136
  • [6] A CONSTANT FLUX OF CARBON-DIOXIDE INJECTED INTO THE AIRWAYS MIMICS METABOLIC CARBON-DIOXIDE IN EXERCISE
    MUSSELL, MJ
    PAULEV, PE
    MIYAMOTO, Y
    NAKAZONO, Y
    SUGAWARA, T
    JAPANESE JOURNAL OF PHYSIOLOGY, 1990, 40 (06) : 877 - 891
  • [7] CARBON-DIOXIDE IN KIMBERLITIC MELTS
    BREY, GP
    KOGARKO, LN
    RYABCHIKOV, ID
    NEUES JAHRBUCH FUR MINERALOGIE-MONATSHEFTE, 1991, (04): : 159 - 168
  • [8] PROSPECTS FOR THE UTILIZATION OF CARBON-DIOXIDE
    ARESTA, M
    QUARANTA, E
    TOMMASI, I
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (5-8) : 495 - 504
  • [9] OXIDATION OF VANADIUM BY CARBON-DIOXIDE
    BOUZOUITA, K
    DESMAISON, J
    BILLY, M
    JOURNAL OF THE LESS-COMMON METALS, 1985, 106 (01): : 153 - 163
  • [10] REVIVAL OF CARBON-DIOXIDE AS A REFRIGERANT
    LORENTZEN, G
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (05): : 292 - 301