DETERMINATION OF PROTEOLYTIC-ENZYMES BY FLOW-INJECTION ANALYSIS

被引:1
|
作者
NICOLAS, P
LAMY, A
REYMOND, S
机构
[1] Nestlé Research Centre, Nestec Ltd, CH-1000 Lausanne 26, Vers-chez-les-Blanc
关键词
D O I
10.1016/0003-2697(91)90185-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitation of proteolytic enzymes using N-succinyl-l-Ala-l-Pro-l-Phe-p-nitroanilide has been adapted to flow-injection analysis. This procedure has been developed using two different proteases: subtilisin and chymotrypsin. For both enzymes the influence of substrate concentration on spectrophotometric response has been studied. The assay is based on the merging zones technique combined with a washing step. Results are obtained in less than 15 s and samples may be run at a rate of 90/h with good reproducibility. A linear relation between peak heights and enzyme concentrations was observed for 0-0.15 Anson unit/liter of subtilisin and for 0-30 mg/liter of a commercial preparation of chymotrypsin. The method requires only small sample volumes, and the consumption of the chromogenic substrate is reduced to a minimum by using intermittent pumping. © 1991.
引用
收藏
页码:70 / 73
页数:4
相关论文
共 50 条
  • [31] COMBINING FLOW-INJECTION ANALYSIS AND IMMOBILIZED ENZYMES FOR RAPID AND ACCURATE DETERMINATION OF SERUM GLUCOSE
    NARINESINGH, D
    STOUTE, VA
    DAVIS, G
    SHAAMA, F
    NGO, TT
    ANALYTICAL LETTERS, 1991, 24 (05) : 727 - 747
  • [32] INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF ETHANOL AND ACETALDEHYDE IN WINES BY FLOW-INJECTION ANALYSIS AND IMMOBILIZED ENZYMES
    LAZARO, F
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICAL CHEMISTRY, 1987, 59 (14) : 1859 - 1863
  • [33] IMPROVED METHOD FOR AUTOMATIC DETERMINATION OF PROTEOLYTIC-ENZYMES IN WASHING AGENTS USING PRINCIPLE OF CONTINUOUS-FLOW ANALYSIS
    PFEIFFER, H
    LANGE, KH
    FETTE SEIFEN ANSTRICHMITTEL, 1973, 75 (07): : 438 - &
  • [35] AUTOMATIC LACTATE DETERMINATION BY FLOW-INJECTION ANALYSIS
    RYDEVIK, U
    NORD, L
    INGMAN, F
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1982, 3 (01) : 47 - 49
  • [36] TURBIDIMETRIC DETERMINATION OF PHENFORMIN BY FLOW-INJECTION ANALYSIS
    CALATAYUD, JM
    SAMPEDRO, AS
    ANALUSIS, 1989, 17 (07) : 413 - 416
  • [37] SELECTIVE DETERMINATION OF HISTAMINE BY FLOW-INJECTION ANALYSIS
    HUNGERFORD, JM
    WALKER, KD
    WEKELL, MM
    LAROSE, JE
    THROM, HR
    ANALYTICAL CHEMISTRY, 1990, 62 (18) : 1971 - 1976
  • [38] DETERMINATION OF PHENOL IN WATER BY FLOW-INJECTION ANALYSIS
    MOLLER, J
    MARTIN, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06): : 728 - 731
  • [39] DETERMINATION OF OXALATE IN URINE BY FLOW-INJECTION ANALYSIS
    GAETANI, E
    LAURERI, CF
    VITTO, M
    BORGHI, L
    ELIA, GF
    NOVARINI, A
    CLINICA CHIMICA ACTA, 1986, 156 (01) : 71 - 75
  • [40] Spectrophotometric determination of morphine by flow-injection analysis
    Fitsev, IM
    Garifzyanov, AR
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (02) : 195 - 197