Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:6
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [41] The measurement of ultrasonographic optic nerve sheath diameter in patients with hyperglycemia
    Donertas, Eda
    Kozaci, Nalan
    Avci, Mustafa
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 137 - 143
  • [42] Multislice computed tomographic measurements of optic nerve sheath diameter in brain injury patients
    Ozsarac, Murat
    Duzgun, Fatih
    Golcuk, Yalcin
    Pabuscu, Yuksel
    Bilge, Adnan
    Irik, Mehmet
    Yilmaz, Halil
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2018, 24 (04): : 316 - 320
  • [43] Ultrasonic measurement of optic nerve sheath diameter in elderly patients with craniocerebral injury
    Qiao, Zhifei
    Wang, Lei
    Li, Shutie
    Li, Yuanli
    Gao, Naikun
    Jia, Liqun
    Liu, Chunyan
    Zhai, Liping
    Li, Fulong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (04): : 3466 - 3472
  • [44] Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
    Liu, Dachuan
    Li, Zhen
    Zhang, Xuxiang
    Zhao, Liping
    Jia, Jianping
    Sun, Fei
    Wang, Yaxing
    Ma, Daqing
    Wei, Wenbin
    BMC NEUROLOGY, 2017, 17
  • [45] Measurement of Optic Nerve Sheath Diameter: Differences between Methods? A Pilot Study
    Giger-Tobler, C.
    Eisenack, J.
    Holzmann, D.
    Pangalu, A.
    Sturm, V.
    Killer, H. E.
    Landau, K.
    Jaggi, G. P.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (04) : 467 - 470
  • [46] Optic nerve sheath diameter measurement as a risk marker for significant intracranial hypertension
    Geeraerts, Thomas
    Dubost, Clement
    BIOMARKERS IN MEDICINE, 2009, 3 (02) : 129 - 137
  • [47] Optic nerve sheath diameter measurement for the paediatric patient with an acute deterioration in consciousness
    Ali, Ahmed
    Mccreary, David J.
    ULTRASOUND JOURNAL, 2023, 15 (01)
  • [48] Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
    Dachuan Liu
    Zhen Li
    Xuxiang Zhang
    Liping Zhao
    Jianping Jia
    Fei Sun
    Yaxing Wang
    Daqing Ma
    Wenbin Wei
    BMC Neurology, 17
  • [49] Optic nerve sheath diameter measurement for the paediatric patient with an acute deterioration in consciousness
    Ahmed Ali
    David J. McCreary
    The Ultrasound Journal, 15
  • [50] Quality assessment of optic nerve sheath diameter ultrasonography: Scoping literature review and Delphi protocol
    Hirzallah, Mohammad, I
    Lochner, Piergiorgio
    Hafeez, Muhammad Ubaid
    Lee, Andrew G.
    Krogias, Christos
    Dongarwar, Deepa
    Manchanda, Ramneek
    Ouellette, Lara
    Hartman, Nicholas D.
    Ertl, Michael
    Schlachetzki, Felix
    Robba, Chiara
    JOURNAL OF NEUROIMAGING, 2022, 32 (05) : 808 - 824