Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:7
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [31] Optic Nerve Sheath Diameter and Acute Mountain Sickness
    Keyes, Linda E.
    Paterson, Ryan
    Boatright, Dowin
    Browne, Vaughn
    Leadbetter, Gig
    Hackett, Peter
    WILDERNESS & ENVIRONMENTAL MEDICINE, 2013, 24 (02) : 105 - 111
  • [32] Optic nerve sheath diameter based on preoperative brain computed tomography and intracranial pressure are positively correlated in adults with hydrocephalus
    Lee, Hyung-Chul
    Lee, Won-Jong
    Dho, Yun-Sik
    Cho, Won-Sang
    Kim, Yong Hwy
    Park, Hee-Pyoung
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 167 : 31 - 35
  • [33] Determination of ventriculoperitoneal shunt dysfunction using optic nerve sheath diameter measurement on CT scan in pediatric patients with hydrocephalus
    Aydin Ozturk, Pinar
    Asena, Muhammet
    CHILDS NERVOUS SYSTEM, 2021, 37 (06) : 1895 - 1900
  • [34] Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke
    Guo, Yuan
    Chen, Yinjuan
    Shen, Chaoxiong
    Fan, Daofeng
    Hu, Xiaohong
    Duan, Jiaojiao
    Chen, Yangui
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [35] Variability of the optic nerve sheath diameter on brain computed tomography in Turkish children based on sex and age
    Bardak, Sefika
    Berksoy, Emel
    Cicek, Alper
    Demir, Guelsah
    Pekcevik, Yeliz
    Elibol, Pelin
    Verdi, Ezgi Guvel
    Gökalp, Gamze
    Nalbant, Tugce
    Emir, Busra
    CHILDS NERVOUS SYSTEM, 2023, 39 (12) : 3551 - 3560
  • [36] Optic nerve sheath diameter on computed tomography not predictive of neurological status post-cardiac arrest
    Rush, Barret
    Wormsbecker, Andrew
    Berger, Landon
    Wiskar, Katie
    Sekhon, Mypinder S.
    Griesdale, Donald E.
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2017, 19 (03) : 181 - 185
  • [37] Bedside sonographic measurements of optic nerve sheath diameter in children with diabetic ketoacidosis
    Sik, Nihan
    Erbas, Ibrahim Mert
    Demir, Korcan
    Yilmaz, Durgul
    Duman, Murat
    PEDIATRIC DIABETES, 2021, 22 (04) : 618 - 624
  • [38] Measurement of changes in optic nerve sheath diameter using ultrasound and computed tomography scan before and after the ventriculoperitoneal shunt surgery in patients with hydrocephalus-A prospective observational trial
    Bhandari, Deepak
    Bidkar, Prasanna Udupi
    Adinarayanan, S.
    Narmadhalakshmi, K.
    Srinivasan, S.
    BRITISH JOURNAL OF NEUROSURGERY, 2019, 33 (02) : 125 - 130
  • [39] Computed Tomography Optic Nerve Sheath Diameter-to-Eyeball Transverse Diameter Ratio as a Novel Noninvasive Parameter for Prognostication in Traumatic Brain Injury
    Sharma, Praveen K.
    Natarajan, Paarthipan
    Ramakrishnan, Karthik Krishna
    Aram, Arun
    Subramonian, Sakthi Ganesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [40] Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients
    Mathews, Alvin
    Cattamanchi, Srihari
    Panneerselvam, Tamilanbu
    Trichur, Ramakrishnan, V