Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:7
|
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [21] The Measurement of Elderly Volunteers' Optic Nerve Sheath Diameters by Ocular Ultrasonography
    Avci, Mustafa
    Kozaci, Nalan
    Komut, Erdal
    Komut, Seval
    Caliskan, Gulsum
    Tulubas, Gul
    MEDICINA-LITHUANIA, 2019, 55 (08):
  • [22] Transorbital ultrasound measurement of optic nerve sheath diameter in normal rabbits
    Yang, Xi-Yue
    Yang, Jin-Ping
    Zhu, Lin-Ping
    Pan, Rui-Hui
    Huang, Yan-Ni
    Li, Zhi-Xian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 13412 - 13418
  • [23] Optic nerve sheath diameter measurement for prediction of postdural puncture headache
    Boyaci, Semih
    Onay, Meryem
    Gulec, Mehmet Sacit
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (02) : 415 - 422
  • [24] The role of optic nerve sheath diameter measurement in the diagnosis of brain death
    Gulsoy, K. Yetis
    Orhan, S.
    Ozturk, S. Burkay
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (13) : 5993 - 5999
  • [25] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204
  • [26] Measurement of optic nerve sheath diameter by ultrasound in healthy term neonates
    Lan, Shih-Yun
    Tai, Hung-Lin
    Lin, Jainn-Jim
    Lan, Fan-Yun
    Tsai, Hsin-Yu
    Lin, Kuang-Lin
    PEDIATRICS AND NEONATOLOGY, 2021, 62 (06) : 591 - 597
  • [27] Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol
    Pansell, Jakob
    Bell, Max
    Rudberg, Peter
    Friman, Ola
    Cooray, Charith
    JOURNAL OF NEUROIMAGING, 2022, 32 (01) : 104 - 110
  • [28] Ultrasonographic measurement of the optic nerve sheath diameter in dysthyroid optic neuropathy
    Ji, Xian
    Xiao, Wei
    Ye, Huijing
    Chen, Rongxin
    Wu, Jinghong
    Mao, Yuxiang
    Yang, Huasheng
    EYE, 2021, 35 (02) : 568 - 574
  • [29] Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage
    Naldi, Andrea
    Pivetta, Emanuele
    Coppo, Lorenzo
    Cantello, Roberto
    Comi, Cristoforo
    Stecco, Alessandro
    Cerrato, Paolo
    Lesmeister, Martin
    Lochner, Piergiorgio
    JOURNAL OF NEUROIMAGING, 2019, 29 (03) : 394 - 399
  • [30] Optic nerve sheath diameter measurement for prediction of postdural puncture headache
    Semih Boyacı
    Meryem Onay
    Mehmet Sacit Güleç
    Journal of Clinical Monitoring and Computing, 2024, 38 : 415 - 422