Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:7
|
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [1] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145
  • [2] The evaluation of intracranial pressure evaluation by optic nerve sheath diameter measurement on bedside ultrasonography after ischemic stroke
    Yildiz, Goknur
    Acar, Nurdan
    Cevik, Arif Alper
    Ozdemir, Atilla Ozcan
    Metintas, Selma
    Kaplan, Davut
    Ozakin, Engin
    Yildiz, Can Gokay
    Ayyildiz, Ayse
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 209
  • [3] Comparing ultrasonographic optic nerve sheath diameter to head computed tomography scan to predict intracranial pressure elevation
    Sitanaya, Shierly Novitawati
    Kamayanti, Fadhila
    Nugroho, Hari Adityo
    Prabowo, Bobi
    SAGE OPEN MEDICINE, 2022, 10
  • [4] Measurement of Optic Nerve Sheath Diameter by Computed Tomography in the Pediatric Population: Normal Values
    Akturk, Yeliz
    Simsir, Begum Demirler
    Hekimo, Baki
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2024, 61 (01) : 38 - 43
  • [5] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [6] A-scan ultrasonography and optic nerve sheath diameter evaluation in children with acute liver failure
    De Bernardo, Maddalena
    Vitiello, Livio
    Capone, Michela
    Rosa, Nicola
    LIVER INTERNATIONAL, 2020, 40 (06) : 1504 - 1504
  • [7] Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
    Yanamandra, Uday
    Gupta, Amul
    Bhattachar, Srinivasa A.
    Yanamandra, Sushma
    Das, Subrat K.
    Patyal, Sagarika
    Grewal, Rajan
    Nair, Velu
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (03) : 150 - 153
  • [8] Interrater reliability of emergency medicine residents in measurement of optic nerve sheath diameter with computed tomography
    Yilmaz, Irem Olcay
    Aksay, Ersin
    Bayram, Basak
    Oray, Nese Colak
    Karabay, Nuri
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2021, 21 (03): : 117 - 121
  • [9] Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist: An International Consensus Statement on Optic Nerve Sheath Diameter Imaging and Measurement
    Hirzallah, Mohammad I.
    Lochner, Piergiorgio
    Hafeez, Muhammad Ubaid
    Lee, Andrew G.
    Krogias, Christos
    Dongarwar, Deepa
    Hartman, Nicholas D.
    Ertl, Michael
    Robba, Chiara
    Malojcic, Branko
    Valaikiene, Jurgita
    Sarwal, Aarti
    Hakimi, Ryan
    Schlachetzki, Felix
    CRITICAL CARE MEDICINE, 2024, 52 (10) : 1543 - 1556
  • [10] Prognostic significance of optic nerve sheath diameter on computed tomography scan with severity of blunt traumatic brain injury in the emergency department
    Waheed, Shahan
    Baig, Muhammad Akbar
    Siddiqui, Emaduddin
    Jamil, Danyal
    Bashar, Masharib
    Feroze, Asher
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (02) : 268 - 271