INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM

被引:130
作者
BUTTS, K
RIEDERER, SJ
EHMAN, RL
THOMPSON, RM
JACK, CR
机构
[1] Magnetic Resonance Laboratory, Mayo Clinic, Rochester, Minnesota
关键词
ECHO PLANAR; FAST SCANNING;
D O I
10.1002/mrm.1910310111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes an interleaved echo planar imaging (EPI) method for use on a standard whole body scanner. The data acquisition is divided into two to eight repetitions rather than one to two, as implemented by dedicated EPI systems. Interleaving allows the use of a lower sampling bandwidth with a significant increase in signal-to-noise. The method also has the advantages of relative ease of implementation, no need for postprocessing to remove image distortion, and no need for shimming on a case-by-case basis. The interleaved EPI method was applied to two applications ideally suited to EPI: breathhold T-2-weighted abdominal imaging and functional imaging. In vivo liver-lesion contrast as measured in a 35-patient study showed increased contrast for the interleaved EPI by an average factor of 1.21 (+/-0.34) over conventional spin-echo imaging. CNR measurements showed the EPI to be comparable with conventional spin echo with a relative factor of 1.00 (+/-0.36). Functional imaging with an eight-shot interleaved EPI sequence provided 128 x 128 images of cerebral activation during bilateral finger tapping.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 23 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[3]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[4]  
BRACEWELL RN, 1978, FOURIER TRANSFORM IT, P122
[5]  
BUTTS RK, 1992, J MAGN RESON IMAGING, V2, P285
[6]  
Cho ZH, 1987, 6TH P SMRM ANN M, P912
[7]   ULTRA-FAST IMAGING [J].
COHEN, MS ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :1-37
[8]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[9]  
FARZANEH F, 1989, 8TH ANN M SMRI, P70
[10]  
FARZANEH F, 1988, ANN M RSNA CHICAGO, P379