Factors That Impact Evaluation of Left Ventricular Systolic Parameters in Myocardial Perfusion Gated SPECT with 16 Frame and 8 Frame Acquisition Models

被引:6
作者
Ansari, Mojtaba [1 ]
Hashemi, Hoda [2 ]
Soltanshahi, Mehdi [2 ]
Qutbi, Mohsen [2 ]
Azizmohammadi, Zahra [1 ]
Tabeie, Faraj [2 ]
Javadi, Hamid [3 ]
Jafari, Esmail [4 ]
Barekat, Maryam [5 ]
Assadi, Majid [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Imam Hossein Hosp, Dept Nucl Med, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Taleghani Educ Hosp, Sch Med, Dept Nucl Med, Tehran, Iran
[3] Golestan Univ Med Sci GUOMS, GRCGH, Gorgan, Iran
[4] Bushehr Univ Med Sci, Persian Gulf Nucl Med Res Ctr, Bushehr, Iran
[5] Royan Inst, Regenerat Med Dept, Tehran, Iran
关键词
Perfusion gated SPECT; 16; frames; 8; systolic parameters;
D O I
10.4274/mirt.49368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Evaluating the effects of heart cavity volume, presence and absence of perfusion defect, gender and type of study (stress and rest) on the difference of systolic parameters of myocardial perfusion scan in 16 and 8 framing gated SPECT imaging. Methods: Cardiac gated SPECT in both 16 and 8 framing simultaneously and both stress and rest phases at one-day protocol was performed for 50 patients. Data have been reconstructed by filter back projection (FBP) method and left ventricular (LV) systolic parameters were calculated by using QGS software. The effect of some factors such as LV cavity volume, presence and absence of perfusion defect, gender and type of study on data difference between 8 and 16 frames were evaluated. Results: The differences in ejection fraction (EF), end-diastolic volume (EDV) and end-systolic volume (ESV) in both stress and rest were statistically significant. Difference in both framing was more in stress for EF and ESV, and was more in rest for EDV. Study type had a significant effect on differences in systolic parameters while gender had a significant effect on differences in EF and ESV in rest between both framings. Conclusion: In conclusion, results of this study revealed that difference of both 16 and 8 frames data in systolic phase were statistically significant and it seems that because of better efficiency of 16 frames, it cannot be replaced by 8 frames. Further well-designed studies are required to verify these findings.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 21 条
  • [1] Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: Influence of tracer, gender, and acquisition camera
    Ababneh, AA
    Sciacca, RR
    Kim, B
    Bergmann, SR
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) : 661 - 668
  • [2] Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis
    Berman, Daniel S.
    Kang, Xingping
    Gransar, Heidi
    Gerlach, James
    Friedman, John D.
    Hayes, Sean W.
    Thomson, Louise E. J.
    Hachamovitch, Rory
    Shaw, Leslee J.
    Slomka, Piotr J.
    De Yang, Ling
    Germano, Guido
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (01) : 45 - 53
  • [3] DEPUEY EG, 1993, J NUCL MED, V34, P1871
  • [4] Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods
    Faber, TL
    Vansant, JP
    Pettigrew, RI
    Galt, JR
    Blais, M
    Chatzimavroudis, G
    Cooke, CD
    Folks, RD
    Waldrop, SM
    Gurtler-Krawczynska, E
    Wittry, MD
    Garcia, EV
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) : 645 - 651
  • [5] GERMANO G, 1995, J NUCL MED, V36, P2138
  • [6] EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    Hesse, B
    Tägil, K
    Cuocolo, A
    Anagnostopoulos, C
    Bardiés, M
    Bax, J
    Bengel, F
    Sokole, EB
    Davies, G
    Dondi, M
    Edenbrandt, L
    Franken, P
    Kjaer, A
    Knuuti, J
    Lassmann, M
    Ljungberg, M
    Marcassa, C
    Marie, PY
    McKiddie, F
    O'Connor, M
    Prvulovich, E
    Underwood, R
    van Eck-Smit, B
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (07) : 855 - 897
  • [7] Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: Comparison with multigated equilibrium radionuclide angiography
    Kumita, S
    Cho, K
    Nakajo, H
    Toba, M
    Uwamori, M
    Mizumura, S
    Kumazaki, T
    Sano, J
    Sakai, S
    Munakata, K
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (05) : 568 - 574
  • [8] Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters
    Kurisu, Satoshi
    Sumimoto, Yoji
    Ikenaga, Hiroki
    Watanabe, Noriaki
    Ishibashi, Ken
    Dohi, Yoshihiro
    Fukuda, Yukihiro
    Kihara, Yasuki
    [J]. HEART AND VESSELS, 2017, 32 (07) : 790 - 795
  • [9] Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard
    Kurisu, Satoshi
    Iwasaki, Toshitaka
    Abe, Nobukazu
    Tamura, Megumi
    Ikenaga, Hiroki
    Watanabe, Noriaki
    Higaki, Tadanao
    Shimonaga, Takashi
    Ishibashi, Ken
    Dohi, Yoshihiro
    Fukuda, Yukihiro
    Kihara, Yasuki
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (11) : 1127 - 1133
  • [10] Manrique A, 1999, J NUCL MED, V40, P805