摘要
Two passive filter circuit designs are compared which enable series resonant trapezoidal drive of the modulated read gradients used in both echo-planar and echo-volumar imaging. Using simple circuit simulation software, details of the expected power requirements and performance have been evaluated for peak operating currents of up to 1000 A. The circuits evaluated were of a 7th order design incorporating a 110 mu H gradient coil operating at fundamental frequencies between 800 Hz and 2000 Hz. Results indicate that the simpler circuit design is not necessarily the most efficient. In addition, by suitable modification of the input waveform algorithm, it can be shown that the shape of the resonant gradient waveform may be varied entirely under software control from triangular to trapezoidal, the minimum ramptime being specified by the highest harmonic accommodated in the circuit. The energy storage, non-dissipative nature of the circuit design also means that the gradient ramptime is effectively independent of amplifier power capabilities, making a fast rise trapezoidal waveform as easy to implement as either triangular or sinusoidal waveforms. Using the approach outlined above, trapezoidal gradient modulation at peak current amplitudes in excess of 320 A and risetimes less than 60 mu s have been easily produced in this laboratory for use in echo-planar imaging and for investigations into ways of optimising gradient performance before the onset of peripheral nerve stimulation.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [31] Echo-planar imaging of porous media with spatial resolution below 100 μm
    Manz, B
    Chow, PS
    Gladden, LF
    JOURNAL OF MAGNETIC RESONANCE, 1999, 136 (02) : 226 - 230
  • [32] Detection of cholesteatoma: 2D BLADE turbo gradient- and spin-echo imaging versus readout-segmented echo-planar diffusion-weighted imaging
    Lin, Mengyan
    Lin, Naier
    Sheng, Yaru
    Sha, Yan
    Zhang, Zhongshuai
    Zhou, Kun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5223 - 5229
  • [33] ASSESSING TRAUMATIC BRAIN INJURY WITH ACCELERATED SUSCEPTIBILITY WEIGHTED IMAGING USING SEGMENTED ECHO-PLANAR IMAGING
    Wang, Wen-Tung
    Li, Ningzhi
    Chan, Leighton
    Dzung Pham
    Butman, John
    JOURNAL OF NEUROTRAUMA, 2012, 29 (10) : A86 - A87
  • [34] Segmented diffusion imaging with iterative motion-corrected reconstruction (SEDIMENT) for brain echo-planar imaging
    Steinhoff, Malte
    Nehrke, Kay
    Mertins, Alfred
    Boernert, Peter
    NMR IN BIOMEDICINE, 2020, 33 (12)
  • [35] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [36] Fast 3D radiofrequency field mapping using echo-planar imaging
    Jiru, F.
    Klose, U.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1375 - 1379
  • [37] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [38] A Theoretical Approach for Familiarization with Techniques of Interleaved Echo-Planar Imaging for Functional Magnetic Resonance Imaging and Their Features
    Rahman, Md. Manzur
    Talukder, Abdul Hafiz Ibne
    2008 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTING SCIENCE AND AUTOMATIC CONTROL (CCE 2008), 2008, : 113 - 118
  • [39] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [40] Comparison of the Image Quality of Turbo Spin Echo and Echo-Planar Diffusion-Weighted Imaging of the Head and Neck Region
    Sam, Ajina
    Misbah, Iffath
    Ram, Jasvant
    Raja, Sam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)