RESONANT TRAPEZOIDAL GRADIENT GENERATION FOR USE IN ECHO-PLANAR IMAGING

被引:5
|
作者
HARVEY, PR [1 ]
MANSFIELD, P [1 ]
机构
[1] UNIV NOTTINGHAM,DEPT PHYS,CTR MAGNET RESONANCE,NOTTINGHAM,ENGLAND
关键词
GRADIENT GENERATION; FAST MRI; EPI;
D O I
10.1016/0730-725X(94)92356-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two passive filter circuit designs are compared which enable series resonant trapezoidal drive of the modulated read gradients used in both echo-planar and echo-volumar imaging. Using simple circuit simulation software, details of the expected power requirements and performance have been evaluated for peak operating currents of up to 1000 A. The circuits evaluated were of a 7th order design incorporating a 110 mu H gradient coil operating at fundamental frequencies between 800 Hz and 2000 Hz. Results indicate that the simpler circuit design is not necessarily the most efficient. In addition, by suitable modification of the input waveform algorithm, it can be shown that the shape of the resonant gradient waveform may be varied entirely under software control from triangular to trapezoidal, the minimum ramptime being specified by the highest harmonic accommodated in the circuit. The energy storage, non-dissipative nature of the circuit design also means that the gradient ramptime is effectively independent of amplifier power capabilities, making a fast rise trapezoidal waveform as easy to implement as either triangular or sinusoidal waveforms. Using the approach outlined above, trapezoidal gradient modulation at peak current amplitudes in excess of 320 A and risetimes less than 60 mu s have been easily produced in this laboratory for use in echo-planar imaging and for investigations into ways of optimising gradient performance before the onset of peripheral nerve stimulation.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [21] Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI
    Jung, Kwan-Jin
    Zhao, Tiejun
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 419 - 427
  • [22] The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging
    Porter, DA
    Calamante, F
    Gadian, DG
    Connelly, A
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 385 - 392
  • [23] Referenceless distortion correction of gradient-echo echo-planar imaging under inhomogeneous magnetic fields based on a deep convolutional neural network
    Liao, Pu
    Zhang, Jun
    Zeng, Kun
    Yang, Yonggui
    Cai, Shuhui
    Guo, Gang
    Cai, Congbo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 100 : 230 - 238
  • [24] Improvements in Parallel Imaging Accelerated Functional MRI Using Multiecho Echo-Planar Imaging
    Schmiedeskamp, Heiko
    Newbould, Rexford D.
    Pisani, Laura J.
    Skare, Stefan
    Glover, Gary H.
    Pruessmann, Klaas P.
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 959 - 969
  • [25] AVOIDING PERIPHERAL-NERVE STIMULATION - GRADIENT WAVE-FORM CRITERIA FOR OPTIMUM RESOLUTION IN ECHO-PLANAR IMAGING
    HARVEY, PR
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) : 236 - 241
  • [26] Minimization of Nyquist Ghosting for Echo-Planar Imaging at Ultra-High Fields Based on a "Negative Readout Gradient" Strategy
    van der Zwaag, Wietske
    Marques, Jose P.
    Lei, Hongxia
    Just, Nathalie
    Kober, Tobias
    Gruetter, Rolf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1171 - 1178
  • [27] A novel object-independent "balanced" reference scan for echo-planar imaging
    Reeder, SB
    Faranesh, AZ
    Atalar, E
    McVeigh, ER
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (06): : 847 - 852
  • [28] MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING
    KWONG, KK
    CHESLER, DA
    WEISSKOFF, RM
    DONAHUE, KM
    DAVIS, TL
    OSTERGAARD, L
    CAMPBELL, TA
    ROSEN, BR
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 878 - 887
  • [29] 'Snap-shot' velocity vector mapping using echo-planar imaging
    Tayler, Alexander B.
    Sederman, Andrew J.
    Newling, Benedict
    Mantle, Mick D.
    Gladden, Lynn F.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 204 (02) : 266 - 272
  • [30] ADEPT: Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs
    Shafieizargar, Banafshe
    Jeurissen, Ben
    Poot, Dirk H. J.
    Klein, Stefan
    Van Audekerke, Johan
    Verhoye, Marleen
    den Dekker, Arnold J.
    Sijbers, Jan
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 396 - 410