RESONANT TRAPEZOIDAL GRADIENT GENERATION FOR USE IN ECHO-PLANAR IMAGING

被引:5
|
作者
HARVEY, PR [1 ]
MANSFIELD, P [1 ]
机构
[1] UNIV NOTTINGHAM,DEPT PHYS,CTR MAGNET RESONANCE,NOTTINGHAM,ENGLAND
关键词
GRADIENT GENERATION; FAST MRI; EPI;
D O I
10.1016/0730-725X(94)92356-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two passive filter circuit designs are compared which enable series resonant trapezoidal drive of the modulated read gradients used in both echo-planar and echo-volumar imaging. Using simple circuit simulation software, details of the expected power requirements and performance have been evaluated for peak operating currents of up to 1000 A. The circuits evaluated were of a 7th order design incorporating a 110 mu H gradient coil operating at fundamental frequencies between 800 Hz and 2000 Hz. Results indicate that the simpler circuit design is not necessarily the most efficient. In addition, by suitable modification of the input waveform algorithm, it can be shown that the shape of the resonant gradient waveform may be varied entirely under software control from triangular to trapezoidal, the minimum ramptime being specified by the highest harmonic accommodated in the circuit. The energy storage, non-dissipative nature of the circuit design also means that the gradient ramptime is effectively independent of amplifier power capabilities, making a fast rise trapezoidal waveform as easy to implement as either triangular or sinusoidal waveforms. Using the approach outlined above, trapezoidal gradient modulation at peak current amplitudes in excess of 320 A and risetimes less than 60 mu s have been easily produced in this laboratory for use in echo-planar imaging and for investigations into ways of optimising gradient performance before the onset of peripheral nerve stimulation.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [1] Referenceless interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Faranesh, AZ
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 87 - 94
  • [2] Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI)
    Chen, Nan-kuei
    Oshio, Koichi
    Panych, Lawrence P.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 916 - 924
  • [3] Accelerated silent echo-planar imaging
    Liebig, Patrick
    Heidemann, Robin M.
    Hensel, Bernhard
    Porter, David A.
    MAGNETIC RESONANCE IMAGING, 2019, 55 : 81 - 85
  • [4] Motion robust GRAPPA for echo-planar imaging
    Baron, Corey A.
    Beaulieu, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1166 - 1174
  • [5] Correction of Shearing Distortions in Echo-Planar Imaging
    Liu, Guoxiang
    Oshio, Koichi
    Ogawa, Seiji
    Murata, Tsutomu
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) : 2628 - 2634
  • [6] Correction of shear artifact caused by unbalanced alternating readout gradient in echo-planar Imaging
    Chiou, JY
    Ahn, CB
    Muftuler, LT
    Nalcioglu, O
    PHYSICA MEDICA, 2003, 19 (02) : 175 - 179
  • [7] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [8] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300
  • [9] Three dimensional echo-planar imaging at 7 Tesla
    Poser, B. A.
    Koopmans, P. J.
    Witzel, T.
    Wald, L. L.
    Barth, M.
    NEUROIMAGE, 2010, 51 (01) : 261 - 266
  • [10] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    FRONTIERS IN NEUROSCIENCE, 2022, 16