TRACE ELEMENTAL ANALYSIS AT NANOMETER SPATIAL-RESOLUTION BY PARALLEL-DETECTION ELECTRON-ENERGY-LOSS SPECTROSCOPY

被引:31
作者
LEAPMAN, RD [1 ]
NEWBURY, DE [1 ]
机构
[1] NBS, MICROANAL RES GRP, GAITHERSBURG, MD 20899 USA
关键词
D O I
10.1021/ac00066a003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel-detection electron energy loss spectroscopy (EELS) combined with scanning transmission electron microscopy (STEM) and a field emission source provides an unprecedented sensitivity for elemental microanalysis. By deflecting the energy loss spectrum across a parallel detector and computing the difference spectrum from sequentially collected energy-shifted spectra, the effects due to detector pattern noise are nearly eliminated so that signals less than 0.1% of the background can be readily detected. Measurements on a series of glass standard reference materials show that EELS provides both high spatial resolution and trace sensitivity at the 10 atomic ppm level for a wide range of elements including the alkaline earths, 3-d transition metals, and the lanthanides. For analytical volumes with dimensions of the order of 10 nm, this translates into near-single atom detectability.
引用
收藏
页码:2409 / 2414
页数:6
相关论文
共 50 条
  • [31] DETECTION OF VARIOUS ELEMENTS IN PLANT-CELLS USING ELECTRON-ENERGY-LOSS SPECTROSCOPY
    LEHMANN, H
    KRAMER, A
    SCHULZ, D
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1987, 44 : 34 - 34
  • [32] DETERMINATION OF THE CRYSTAL-FIELD STRENGTH IN MANGANESE COMPOUNDS BY PARALLEL ELECTRON-ENERGY-LOSS SPECTROSCOPY
    GARVIE, LAJ
    CRAVEN, AJ
    ELECTRON MICROSCOPY AND ANALYSIS 1993, 1993, (138): : 31 - 34
  • [33] STUDY OF DISSOCIATION OF WATER ON GE(100) BY HIGH-RESOLUTION ELECTRON-ENERGY-LOSS SPECTROSCOPY
    PAPAGNO, L
    FRANKEL, D
    CHEN, Y
    CAPUTI, LS
    ANDERSON, J
    LAPEYRE, GJ
    SURFACE SCIENCE, 1991, 248 (03) : 343 - 348
  • [34] HIGH-RESOLUTION ELECTRON-ENERGY-LOSS SPECTROSCOPY OF AMORPHOUS-GERMANIUM AND SILICON FILMS
    SCHRODER, B
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (03): : 388 - 388
  • [35] A HIGH-SENSITIVITY CCD SYSTEM FOR PARALLEL ELECTRON-ENERGY-LOSS SPECTROSCOPY (CCD FOR EELS)
    TANG, Z
    HO, R
    XU, Z
    SHAO, Z
    SOMLYO, AP
    JOURNAL OF MICROSCOPY-OXFORD, 1994, 175 : 100 - 107
  • [36] THE APPLICATION OF ELECTRON-ENERGY-LOSS SPECTROSCOPY TO THE ANALYSIS OF ULTRAFINE AEROSOL-PARTICLES
    MAYNARD, AD
    JOURNAL OF AEROSOL SCIENCE, 1995, 26 (05) : 757 - 777
  • [37] ELECTRON-ENERGY-LOSS SPECTROSCOPY (EELS) - COMPARISON WITH X-RAY-ANALYSIS
    MULLEJANS, H
    BRULEY, J
    JOURNAL DE PHYSIQUE IV, 1993, 3 (C7): : 2083 - 2092
  • [38] ADSORPTION OF CHLORINE ON GAAS(110) INVESTIGATED BY HIGH-RESOLUTION ELECTRON-ENERGY-LOSS SPECTROSCOPY
    PANKRATZ, J
    NIENHAUS, H
    MONCH, W
    SURFACE SCIENCE, 1994, 307 : 211 - 215
  • [39] Limits to the spatial, energy and momentum resolution of electron energy-loss spectroscopy
    Egerton, R. F.
    ULTRAMICROSCOPY, 2007, 107 (08) : 575 - 586
  • [40] HYDROGEN ADSORPTION ON RH(110) STUDIED BY HIGH-RESOLUTION ELECTRON-ENERGY-LOSS SPECTROSCOPY
    MUSSIG, HJ
    STENZEL, W
    SONG, Y
    CONRAD, H
    SURFACE SCIENCE, 1994, 311 (03) : 295 - 307