IMPROVED J-COMPENSATED APT EXPERIMENTS

被引:22
|
作者
TORRES, AM
NAKASHIMA, TT
MCCLUNG, RED
机构
[1] Department of Chemistry, University of Alberta, Edmonton
关键词
D O I
10.1006/jmra.1993.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The derivation and investigation of two new J-compensated attached-proton-test experiments, CAPT2 and CAPT3, are presented. These methods incorporate fewer pulses than CAPT and are shown to be more effective over a wider range of 1JCH than spin flip, APT, and CAPT for CH, CH2, and CH3 spin systems. In addition, the magnitude of the flip angle of the initial pulse which creates transverse carbon magnetization is unrestricted in CAPT2 and CAPT3. The compensated CAPT3 sequence, which is patterned after the 90°x90°y90°x composite pulse, is found to be excellent for routine use in 13C spectroscopy. © 1993 by Academic Press, Inc.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [21] Relaxation-compensated fast multislice amide proton transfer (APT) imaging of acute ischemic stroke
    Sun, Phillip Zhe
    Murata, Yoshihiro
    Lu, Jie
    Wang, Xiaoying
    Lo, Eng H.
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1175 - 1182
  • [22] Improved compression of motion-compensated residuals
    Poh, W
    Monro, DM
    2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL I, PROCEEDINGS, 2002, : 725 - 728
  • [23] Review of glass fibre grid use for pavement reinforcement and APT experiments at IFSTTAR
    Mai-Lan Nguyen
    Blanc, Juliette
    Kerzreho, Jean-Pierre
    Hornych, Pierre
    ROAD MATERIALS AND PAVEMENT DESIGN, 2013, 14 : 287 - 308
  • [24] A curvature-compensated bandgap reference with improved PSRR
    Xiao, D
    Li, WM
    Zhu, XF
    Fu, XD
    2005 6TH INTERNATIONAL CONFERENCE ON ASIC PROCEEDINGS, BOOKS 1 AND 2, 2005, : 548 - 551
  • [25] Analysis on the current formation of an improved compensated pulsed alternator
    Gao, Liang
    Li, Zhenxiao
    Li, Baoming
    Gao, L. (Quantumlab@163.com), 1600, Science Press (40): : 1116 - 1120
  • [26] IMPROVED ENVIRONMENTAL CORRECTIONS FOR COMPENSATED NEUTRON LOGS.
    Galford, J.E.
    Flaum, C.
    Gilchrist Jr., W.A.
    Soran, P.D.
    Gardner, J.S.
    SPE Formation Evaluation, 1988, 3 (02): : 371 - 376
  • [27] IMPROVED ASTIGMATICALLY COMPENSATED RESONATOR FOR CW DYE LASERS
    JOHNSTON, WD
    RUNGE, PK
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1972, QE 8 (08) : 724 - &
  • [28] IMPROVED QUANTITATIVE APT TEST FOR DETECTING FETAL HEMOGLOBIN IN BLOODY STOOLS OF NEWBORNS
    LIU, N
    WU, AHB
    WONG, SS
    CLINICAL CHEMISTRY, 1993, 39 (11) : 2326 - 2329
  • [29] ALGONQUIN EXPERIMENTS - PENMAN,J
    WEINER, DH
    JOURNAL OF PARAPSYCHOLOGY, 1978, 42 (04) : 328 - 328
  • [30] EXPERIMENTS IN CONTRADICTION - PIAGET,J
    DEVRIES, R
    AMERICAN JOURNAL OF EDUCATION, 1982, 90 (02) : 196 - 201