EVALUATION OF NONINVASIVE BLOOD-PRESSURE MONITORING DEVICES SPACELAB-90202 AND SPACELAB-90207 VERSUS RESTING AND AMBULATORY 24-HOUR INTRAARTERIAL BLOOD-PRESSURE

被引:147
作者
GROPPELLI, A
OMBONI, S
PARATI, G
MANCIA, G
机构
[1] UNIV MILAN,OSPED SAN GERARDO MONTE & TERAPIA MED,CATTEDRA MED INTERNA,I-20122 MILAN,ITALY
[2] OSPED MAGGIDRE,CTR FISIOL CLIN & IPERTENS,MILAN,ITALY
[3] CTR AUXOL ITALIANO PIANCAVALLO,MILAN,ITALY
关键词
BLOOD PRESSURE MONITORS; BLOOD PRESSURE MEASUREMENT; 24-HOUR BLOOD PRESSURE PROFILES; AMBULATORY BLOOD PRESSURE MONITORING;
D O I
10.1161/01.HYP.20.2.227
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study evaluated the accuracy of blood pressure values provided by the Spacelabs 90202 and 90207 devices in comparison with intra-arterial recording in 19 subjects at rest and in nine subjects in ambulatory conditions (Oxford method). At rest Spacelabs monitors reflected intra-arterial systolic blood pressure values very closely but overestimated to a considerable extent intra-arterial diastolic blood pressure (Spacelabs-intra-arterial differences, -0.8+/-9.2, NS, and 9.1+/-8.8 mm Hg, p<0.01, for systolic and diastolic blood pressures, respectively). In ambulatory conditions Spacelabs-intra-arterial average differences in 24-hour values were +0.4+/-5.1 mm Hg for systolic blood pressure (NS) and +14.0+/-2.9 mm Hg for diastolic blood pressure (p<0.01) when group data were considered. The performance of both Spacelabs devices was worse when assessed in individual subjects or for each hourly interval. In spite of these differences between noninvasive and intra-arterial absolute blood pressure values, however, Spacelabs 90202 and 90207 monitors were able to faithfully reflect directional hour-to-hour changes in intra-arterial blood pressure (chi-2=18.2 and chi-2=23.1 for systolic and diastolic blood pressures, respectively, p<0.01). No differences were found between the performance of the two Spacelabs devices. Thus, although the absolute accuracy of blood pressure values provided by these monitors in ambulatory subjects is still limited, they seem to be suitable for studies aimed at assessing 24-hour blood pressure profiles quantitatively as well as qualitatively.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 50 条
  • [41] Tolerance intervals for 24-hour ambulatory blood pressure monitoring in the diagnosis of hypertension
    Hermida, RC
    Fernandez, JR
    Calvo, C
    Ayala, DE
    Lopez, JE
    Mojon, A
    Alonso, I
    Dominguez, MJ
    Covelo, M
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 50A - 51A
  • [42] CLINICAL-SIGNIFICANCE OF AMBULATORY BLOOD-PRESSURE MONITORING - EVALUATION OF SEVERITY OF HYPERTENSION, EFFICACY OF TREATMENT AND EFFECTS ON NIGHTTIME BLOOD-PRESSURE
    KATAYAMA, S
    MARUNO, Y
    ITABASHI, A
    INABA, M
    OMOTO, A
    ISHII, J
    JAPANESE HEART JOURNAL, 1991, 32 (01): : 45 - 55
  • [43] SEQUENTIAL SPECTRAL-ANALYSIS OF 24-HOUR BLOOD-PRESSURE AND PULSE INTERVAL IN HUMANS
    PARATI, G
    CASTIGLIONI, P
    DIRIENZO, M
    OMBONI, S
    PEDOTTI, A
    MANCIA, G
    HYPERTENSION, 1990, 16 (04) : 414 - 421
  • [44] CUMULATIVE SUMS ANALYSIS OF 24-HOUR BLOOD-PRESSURE PROFILES IN PATIENTS WITH SYMPATHETIC DENERVATION
    ALAM, M
    PAVITT, DV
    MATHIAS, CJ
    JOURNAL OF HYPERTENSION, 1993, 11 : S286 - S287
  • [45] Is 44-hour better than 24-hour ambulatory blood pressure monitoring in hemodialysis?
    Martin, L. C.
    Franco, R. J. S.
    Gavras, I.
    Matsubara, B. B.
    Okoshi, K.
    Zanati, S. G.
    Caramori, J. T.
    Barretti, P.
    Balbi, A. L.
    Gavras, H.
    KIDNEY & BLOOD PRESSURE RESEARCH, 2006, 29 (05) : 273 - 279
  • [46] 24-Hour blood pressure control by once-daily administration of irbesartan assessed by ambulatory blood pressure monitoring
    Fogari, R
    Ambrosoli, S
    Corradi, L
    Esposti, ED
    Mos, L
    Nami, R
    Nicrosini, F
    Pessina, AC
    Salvetti, A
    Vaccarella, A
    Zanchetti, A
    Martin, A
    Reeves, RA
    JOURNAL OF HYPERTENSION, 1997, 15 (12) : 1511 - 1518
  • [47] NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITORING DURING CLINIC VISIT IN ELDERLY HYPERTENSIVE PATIENTS
    SHIMADA, K
    OGURA, H
    KAWAMOTO, A
    MATSUBAYASHI, K
    ISHIDA, H
    OZAWA, T
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1990, 12 (02) : 151 - 170
  • [48] Characteristics of the 24-hour ambulatory blood pressure monitoring in a COVID-19 survivor
    Wasim, Daanyaal
    Alme, Bjorn
    Jordal, Stina
    Lind Eagan, Tomas Mikal
    Tadic, Marijana
    Mancia, Giuseppe
    Guttormsen, Anne Berit
    Saeed, Sahrai
    FUTURE CARDIOLOGY, 2021, 17 (08) : 1321 - 1326
  • [49] Comparison of 3 Devices for 24-Hour Ambulatory Blood Pressure Monitoring in a Nonclinical Environment Through a Randomized Triale
    Nwankwo, Tatiana
    King, Sallyann M. Coleman
    Ostchega, Yechiam
    Zhang, Guangyu
    Loustalot, Fleetwood
    Gillespie, Cathleen
    Chang, Tiffany E.
    Begley, Elin B.
    George, Mary G.
    Shimbo, Daichi
    Schwartz, Joseph E.
    Muntner, Paul
    Kronish, Ian M.
    Hong, Yuling
    Merritt, Robert
    AMERICAN JOURNAL OF HYPERTENSION, 2020, 33 (11) : 1021 - 1029
  • [50] Association between metabolic syndrome and parameters of 24-hour blood pressure ambulatory monitoring
    Felisbino-Mendes, Mariana Santos
    Gea-Horta, Tatiane
    Pinho Ribeiro, Antonio Luiz
    Kac, Gilberto
    de Fatima Silqueira, Salete Maria
    Velasquez-Melendez, Gustavo
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2011, 55 (06) : 383 - 388