FORMATION OF THROMBIN-ANTITHROMBIN-III COMPLEX USING POLYAMIDE AND HEMOPHAN DIALYZERS

被引:12
作者
SCHULTZE, G [1 ]
HOLLMANN, S [1 ]
SINAH, P [1 ]
机构
[1] KLINIKUM RUDOLF VIRCHOW,BERLIN,GERMANY
关键词
THROMBIN-ANTITHROMBIN-III COMPLEX; THROMBOGENICITY; HEMODIALYSIS; POLYAMIDE MEMBRANE; HEMOPHAN; HEPARIN;
D O I
10.1177/039139889201500610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recently developed ELISA for the thrombin-antithrombin III complex (TAT) is a sensitive, specific, and simplified means of detecting intravascular coagulation. For further evaluation of the thrombogenicity of a polyamide (P) and a Hemophan (H) hollow-fibre dialyzer a cross-over study was done in ten stable patients on maintenance hemodialysis. At the same doses of heparin (mean bolus of 30 U/kg bw and maintenance doses of 86 U/kg bw), thrombin time and partial thromboplastin time were significantly lower using H. At the end of dialysis TAT was significantly higher in H (mean +/- SEM before HD 3.57 +/- .56, at 240 min 14.9 +/- 6.5 ng/ml, p < 0.05, Wilcoxon-test) than in P (before HD 4.36 +/- .98, at 240 min 8.95 +/- 3.0 ng/ml, p < 0.05 H 240 vs. P 240, Wilcoxon-test). Visible clotting was more pronounced in the H filter. Among other favourable features of blood compatibility the polyamide/polyvinylpyrrolidone copolymer with a hydrophilic/hydrophobic microdomain structure has less thrombogenicity. The modified cellulosic membrane H has advantages in complement activation and leukocyte depression, but thrombogenicity seems less favourable since the incorporated diethyl-amino-ethyl groups with their positive charge bind and inactivate negatively charged heparin.
引用
收藏
页码:370 / 373
页数:4
相关论文
共 17 条
[11]   ENHANCED COAGULATION-FIBRINOLYSIS IN PATIENTS ON REGULAR HEMODIALYSIS-TREATMENT [J].
NAKAMURA, Y ;
CHIDA, Y ;
TOMURA, S .
NEPHRON, 1991, 58 (02) :201-204
[12]  
PANICHI A, 1989, BLOOD PURIFICAT, V7, P266
[13]  
PELZER H, 1988, THROMB HAEMOSTASIS, V59, P101
[14]   HEPARIN BINDING AND RELEASE PROPERTIES OF DEAE CELLULOSE MEMBRANES [J].
SCHMITT, E ;
HOLTZ, M ;
KLINKMANN, H ;
ESTHER, G ;
COURTNEY, JM .
BIOMATERIALS, 1983, 4 (04) :309-313
[15]   EFFECT OF DIALYZER MEMBRANES ON INVITRO GENERATION OF EICOSANOIDS [J].
SCHULTZE, G ;
WAGNER, K ;
NEUMAYER, HH ;
FITZNER, R ;
MOLZAHN, M .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1987, 10 (04) :275-278
[16]   EFFECT OF HEMODIALYSIS ON CONTACT GROUP OF COAGULATION-FACTORS, PLATELETS, AND LEUKOCYTES [J].
VAZIRI, ND ;
TOOHEY, J ;
PAULE, P ;
ALIKHANI, S ;
HUNG, E .
AMERICAN JOURNAL OF MEDICINE, 1984, 77 (03) :437-441
[17]  
[No title captured]