FORMATION OF THROMBIN-ANTITHROMBIN-III COMPLEX USING POLYAMIDE AND HEMOPHAN DIALYZERS

被引:12
作者
SCHULTZE, G [1 ]
HOLLMANN, S [1 ]
SINAH, P [1 ]
机构
[1] KLINIKUM RUDOLF VIRCHOW,BERLIN,GERMANY
关键词
THROMBIN-ANTITHROMBIN-III COMPLEX; THROMBOGENICITY; HEMODIALYSIS; POLYAMIDE MEMBRANE; HEMOPHAN; HEPARIN;
D O I
10.1177/039139889201500610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recently developed ELISA for the thrombin-antithrombin III complex (TAT) is a sensitive, specific, and simplified means of detecting intravascular coagulation. For further evaluation of the thrombogenicity of a polyamide (P) and a Hemophan (H) hollow-fibre dialyzer a cross-over study was done in ten stable patients on maintenance hemodialysis. At the same doses of heparin (mean bolus of 30 U/kg bw and maintenance doses of 86 U/kg bw), thrombin time and partial thromboplastin time were significantly lower using H. At the end of dialysis TAT was significantly higher in H (mean +/- SEM before HD 3.57 +/- .56, at 240 min 14.9 +/- 6.5 ng/ml, p < 0.05, Wilcoxon-test) than in P (before HD 4.36 +/- .98, at 240 min 8.95 +/- 3.0 ng/ml, p < 0.05 H 240 vs. P 240, Wilcoxon-test). Visible clotting was more pronounced in the H filter. Among other favourable features of blood compatibility the polyamide/polyvinylpyrrolidone copolymer with a hydrophilic/hydrophobic microdomain structure has less thrombogenicity. The modified cellulosic membrane H has advantages in complement activation and leukocyte depression, but thrombogenicity seems less favourable since the incorporated diethyl-amino-ethyl groups with their positive charge bind and inactivate negatively charged heparin.
引用
收藏
页码:370 / 373
页数:4
相关论文
共 17 条
[1]  
BAYER V, 1987, NIEREN HOCHDRUCK, V16, P185
[2]   FLUID PHASE GENERATION OF TERMINAL COMPLEMENT COMPLEX AS A NOVEL INDEX OF BIOINCOMPATIBILITY [J].
DEPPISCH, R ;
SCHMITT, V ;
BOMMER, J ;
HANSCH, GM ;
RITZ, E ;
RAUTERBERG, EW .
KIDNEY INTERNATIONAL, 1990, 37 (02) :696-706
[3]  
Deppisch R, 1992, Contrib Nephrol, V96, P26
[4]  
HOECK JA, 1988, CLIN CHEM, V34, P2058
[5]  
IRELAND HA, 1991, CLIN NEPHROL, V35, P26
[6]   HEMODIALYSIS AND BLOOD-COAGULATION - THE EFFECT OF HEMODIALYSIS ON COAGULATION FACTOR-XIII AND THROMBIN-ANTITHROMBIN-III COMPLEX [J].
KOLB, G ;
FISCHER, W ;
SEITZ, R ;
MULLER, T ;
EGBRING, R ;
LANGE, H ;
HAVEMANN, K .
NEPHRON, 1991, 58 (01) :106-108
[7]  
LINDSAY RM, 1989, REPLACEMENT RENAL FU, P246
[8]  
LONNEMANN G, 1989, KIDNEY INT, V35, P254
[9]   DIALYZER MEMBRANES - EFFECT OF SURFACE-AREA AND CHEMICAL MODIFICATION OF CELLULOSE ON COMPLEMENT AND PLATELET ACTIVATION [J].
MAHIOUT, A ;
MEINHOLD, H ;
KESSEL, M ;
SCHULZE, H ;
BAURMEISTER, U .
ARTIFICIAL ORGANS, 1987, 11 (02) :149-154
[10]  
MOHAMMED SF, 1989, REPLACEMENT RENAL FU, P229