COMPLICATIONS AFTER CT-GUIDED NEEDLE-BIOPSY THROUGH AERATED VERSUS NONAERATED LUNG

被引:91
作者
HARAMATI, LB [1 ]
AUSTIN, JHM [1 ]
机构
[1] COLUMBIA PRESBYTERIAN MED CTR,DEPT RADIOL,NEW YORK,NY 10032
关键词
BIOPSIES; COMPLICATIONS; COMPUTED TOMOGRAPHIC (CT) GUIDANCE; LUNG; BIOPSY; PNEUMOTHORAX;
D O I
10.1148/radiology.181.3.1947096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Findings in patients who underwent computed tomography (CT)-guided percutaneous needle biopsy (n = 131) of lung are described. In those in whom the needle traversed aerated lung, complications developed in 51% (40 of 79). The rate of pneumothorax was 46% (36 of 79). In those in whom the needle did not traverse aerated lung (n = 52), minor hemoptysis in one patient (2%) was the only complication (P < .0001). When a percutaneous CT-guided lung biopsy needle does not traverse aerated lung, the likelihood of complication appears to be slight.
引用
收藏
页码:778 / 778
页数:1
相关论文
共 3 条
[1]   CT AND CHEST RADIOGRAPHY ARE EQUALLY SENSITIVE IN THE DETECTION OF PNEUMOTHORAX AFTER CT-GUIDED PULMONARY INTERVENTIONAL PROCEDURES [J].
MURPHY, FB ;
SMALL, WC ;
WICHMAN, RD ;
CHALIF, M ;
BERNARDINO, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :45-46
[2]   DIFFICULT THORACIC LESIONS - CT-GUIDED BIOPSY EXPERIENCE IN 150 CASES [J].
VANSONNENBERG, E ;
CASOLA, G ;
HO, M ;
NEFF, CC ;
VARNEY, RR ;
WITTICH, GR ;
CHRISTENSEN, R ;
FRIEDMAN, PJ .
RADIOLOGY, 1988, 167 (02) :457-461
[3]   PERCUTANEOUS TRANS-THORACIC NEEDLE-BIOPSY [J].
WESTCOTT, JL .