COMPLICATIONS AFTER CT-GUIDED NEEDLE-BIOPSY THROUGH AERATED VERSUS NONAERATED LUNG

被引:91
作者
HARAMATI, LB [1 ]
AUSTIN, JHM [1 ]
机构
[1] COLUMBIA PRESBYTERIAN MED CTR,DEPT RADIOL,NEW YORK,NY 10032
关键词
BIOPSIES; COMPLICATIONS; COMPUTED TOMOGRAPHIC (CT) GUIDANCE; LUNG; BIOPSY; PNEUMOTHORAX;
D O I
10.1148/radiology.181.3.1947096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Findings in patients who underwent computed tomography (CT)-guided percutaneous needle biopsy (n = 131) of lung are described. In those in whom the needle traversed aerated lung, complications developed in 51% (40 of 79). The rate of pneumothorax was 46% (36 of 79). In those in whom the needle did not traverse aerated lung (n = 52), minor hemoptysis in one patient (2%) was the only complication (P < .0001). When a percutaneous CT-guided lung biopsy needle does not traverse aerated lung, the likelihood of complication appears to be slight.