EFFECTS ON COAGULATION AND FIBRINOLYSIS WITH REDUCED VERSUS FULL SYSTEMIC HEPARINIZATION AND HEPARIN-COATED CARDIOPULMONARY BYPASS

被引:1
作者
OVRUM, E [1 ]
BROSSTAD, F [1 ]
HOLEN, EA [1 ]
TANGEN, G [1 ]
ABDELNOOR, M [1 ]
机构
[1] UNIV OSLO,NATL HOSP,INTERNAL MED RES INST,N-0027 OSLO,NORWAY
关键词
COAGULATION; FIBRINOLYSIS; HEPARIN; CARDIOPULMONARY BYPASS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Extracorporeal circulation with circuits coated with surface-bound heparin has allowed reduced levels of systemic heparinization. Clinical benefits have included reduced postoperative bleeding and less homologous blood usage. However, the effects on the hemostatic and fibrinolytic systems have remained in part unknown. Methods and Results Indications of thrombin generation, platelet activation, and fibrinolytic activity were investigated in patients undergoing coronary artery bypass surgery. Two groups were perfused with cardiopulmonary bypass (CPB) circuits completely coated with surface-bound heparin: one group with low systemic heparin dose (activated clotting time [ACT] >250 seconds; n=17) and a second group having a full heparin dose (ACT >480 seconds; n=18). A third control group was perfused with ordinary uncoated circuits and full heparin dose (n=17). The plasma level of thrombin-antithrombin complex and prothrombin fragment 1.2 increased in all groups during bypass, and somewhat more in both the heparin-coated groups toward the end of CPB, compared with the control group (P<.01). However, the increase during CPB was minimal compared with the major elevation observed 2 hours after surgery in all groups. Platelet release of beta-thromboglobulin increased in all groups (P<.01) during CPB and significantly more in the high-dose group compared with the other two groups (P=.03). Fibrinolytic activities were similar in all groups, and there were no indications of major consumption of coagulation factors. Conclusions Reduced systemic heparinization (ACT >250 seconds) in patients having extracorporeal circulation with completely heparin-coated circuits did not lead to increased thrombogenicity. Thrombin formation remained within low ranges during CPB compared with patients receiving a full heparin dose and with the major elevations observed after surgery.
引用
收藏
页码:2579 / 2584
页数:6
相关论文
共 50 条
  • [41] DECREASED BLOOD-LOSS AFTER CARDIOPULMONARY BYPASS USING HEPARIN-COATED CIRCUIT AND 50-PERCENT REDUCTION OF HEPARIN DOSE
    BOROWIEC, J
    THELIN, S
    BAGGE, L
    HULTMAN, J
    HANSSON, HE
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 26 (03): : 177 - 185
  • [42] Exposure of procoagulant phospholipids on the surface of platelets in patients undergoing cardiopulmonary bypass using non-coated and heparin-coated extracorporeal circuits
    Weerwind, PW
    Caberg, NEH
    Reutelingsperger, CPM
    Lindhout, T
    De Jong, DS
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (08) : 770 - 776
  • [43] A prospective randomized trial comparing the clinical effectiveness and biocompatibility of heparin-coated circuits and PMEA-coated circuits in pediatric cardiopulmonary bypass
    Itoh, Hideshi
    Ichiba, Shingo
    Ujike, Yoshihito
    Douguchi, Takuma
    Kasahara, Shingo
    Arai, Sadahiko
    Sano, Shunji
    PERFUSION-UK, 2016, 31 (03): : 247 - 254
  • [44] Is reduced systemic heparinization justified with heparin-bonded bypass circuits in cardiac surgery? - Experience with and without aprotinin
    Kipfer, B
    Englberger, L
    Gygax, E
    Nydegger, U
    Carrel, T
    TRANSFUSION AND APHERESIS SCIENCE, 2003, 29 (01) : 17 - 24
  • [45] Heparin-coated extracorporeal bypass circuits: Fibrinolysis and coagulation activity in a clinical trial [Heparinbeschichtung des extrakorporalen kreislaufs: Gerinnungsaktivierung, verbrauch und fibrinolyse in einer randomisierten studie an koronarbypasspatienten]
    Martens S.
    Wimmer-Greinecker G.
    Matheis G.
    Feuerbach J.
    Jakob A.
    Scherer M.
    Westphal K.
    Moritz A.
    Zeitschrift für Herz-, Thorax- und Gefäßchirurgie, 1999, 13 (6) : 267 - 272
  • [46] LOW-DOSE HEPARIN VERSUS FULL-DOSE HEPARIN WITH HIGH-DOSE APROTININ DURING CARDIOPULMONARY BYPASS - A PRELIMINARY-REPORT
    VONSEGESSER, LK
    GARCIA, E
    TURINA, MI
    TEXAS HEART INSTITUTE JOURNAL, 1993, 20 (01) : 28 - 32
  • [47] Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery
    Hosoyama, Katsuhiro
    Ito, Koki
    Kawamoto, Shunsuke
    Kumagai, Kiichiro
    Akiyama, Masatoshi
    Adachi, Osamu
    Kawatsu, Satoshi
    Sasaki, Konosuke
    Suzuki, Marina
    Sugawara, Yumi
    Shimizu, Yuya
    Saiki, Yoshikatsu
    JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (03) : 233 - 240
  • [48] Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery
    Katsuhiro Hosoyama
    Koki Ito
    Shunsuke Kawamoto
    Kiichiro Kumagai
    Masatoshi Akiyama
    Osamu Adachi
    Satoshi Kawatsu
    Konosuke Sasaki
    Marina Suzuki
    Yumi Sugawara
    Yuya Shimizu
    Yoshikatsu Saiki
    Journal of Artificial Organs, 2016, 19 : 233 - 240
  • [49] Release of lipopolysaccharide toxicity-modulating proteins in patients undergoing cardiopulmonary bypass using noncoated and heparin-coated extracorporeal circuits - A clinical pilot study
    Bouma, M
    Maessen, J
    Weerwind, P
    Dentener, M
    Fransen, E
    deJong, D
    Buurman, W
    CHEST, 1997, 111 (03) : 577 - 583
  • [50] Synthetic protein treated versus heparin coated cardiopulmonary bypass surfaces: similar clinical results and minor biochemical differences
    Wimmer-Greinecker, G
    Matheis, G
    Martens, S
    Oremek, G
    Abdel-Rahman, U
    Moritz, A
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 (02) : 211 - 217