THE DESIGN OF AN ENERGY-FOCUSING MASS-SPECTROMETER

被引:1
|
作者
DERMOIS, OC
VANLUMMEL, CWJ
机构
[1] Kernfysisch Versneller Instituut, 9747 AA Groningen
关键词
D O I
10.1016/0168-9002(90)90005-Q
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two versions of a recoil mass spectrometer are discussed and compared with respect to their resolution power, solid-angle acceptance and optical properties. One version consists of a quadrupole doublet followed by an electrostatic deflector, a magnet, a second electrostatic deflector and a doublet. In the second version the doublets are replaced by triplets which results in a much better performance. The electrostatic deflectors will have a variable gap and an electrode voltage of ± 300 kV. © 1990.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 50 条
  • [31] KRATOS - A MODULAR-DESIGN MASS-SPECTROMETER
    不详
    ANALUSIS, 1988, 16 (06) : R59 - R59
  • [32] DESIGN CRITERIA ON A MINICYCLOTRON AS A MASS-SPECTROMETER FOR DATING
    CHEN, MB
    GAO, WZ
    LI, DM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02): : 402 - 408
  • [33] DESIGN OF A NEW FOCUSED MULTIPASSAGE MASS-SPECTROMETER
    BOULANGER, P
    BARIL, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 298 (1-3): : 161 - 170
  • [34] AN ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETER MASS-SPECTROMETER
    CALDECOURT, VJ
    ZAKETT, D
    TOU, JC
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 49 (02): : 233 - 251
  • [35] PRISM MASS SPECTROMETER WITH ENERGY FOCUSING
    KELMAN, VM
    RODNIKOV.IV
    FINOGENO.PA
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1971, 16 (01): : 130 - &
  • [36] DOUBLE FOCUSING MASS-SPECTROMETER WITH CROSSED FIELDS AND DOUBLE PLANE CONDENSER
    IOANOVICIU, D
    CUNA, C
    MERCEA, V
    PALIBRODA, N
    REVUE ROUMAINE DE PHYSIQUE, 1986, 31 (08): : 829 - 832
  • [37] DOUBLE FOCUSING MASS-SPECTROMETER WITH ELECTROSTATIC HEXAPOLAR LENSES FOR CORRECTION OF IMAGES
    CUNA, C
    IOANOVICIU, D
    REVUE ROUMAINE DE PHYSIQUE, 1980, 25 (07): : 751 - 758
  • [38] SEQUENTIAL SIMS ISS MEASUREMENTS USING A DOUBLE FOCUSING MASS-SPECTROMETER
    INOUE, M
    SUGIYAMA, Y
    NISHIGAKI, S
    NODA, T
    APPLIED SURFACE SCIENCE, 1988, 33-4 : 138 - 142
  • [39] ION CURRENT SURFACE FOR A DOUBLE FOCUSING MASS-SPECTROMETER OF REVERSED GEOMETRY
    LACEY, MJ
    MACDONALD, CG
    DONCHI, KF
    DERRICK, PJ
    ORGANIC MASS SPECTROMETRY, 1981, 16 (08): : 351 - 357
  • [40] SIMULATED MIKE SPECTRA FROM A CONVENTIONAL DOUBLE FOCUSING MASS-SPECTROMETER
    KEMP, DL
    COOKS, RG
    BEYNON, JH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1976, 21 (1-2): : 93 - 101