Modifying the aggregated wind farm model with a controller

被引:2
作者
Badr, Mohammed. A. [1 ]
Atallah, Ahmed. M. [2 ]
Bayoumi, Mona A. [2 ]
机构
[1] Ain Shams Univ, Dept Elect Engn, Cairo, Egypt
[2] Benha Univ, Dept Elect Engn, Banha, Egypt
来源
ADVANCES IN ENERGY RESEARCH | 2015年 / 3卷 / 03期
关键词
wind farm aggregation model; controller; PMSG and SCIG;
D O I
10.12989/eri.2015.3.3.133
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A large wind farm can be simplified by the aggregated wind farm models for load flow, steady and transient stability studies. When a fault (such as a short circuit) happens in a large wind farm, some of wind turbines trip while others do not. This paper is to design a controller to modify the aggregated wind farm model in the case of one or more unit removed or added from the complete model. This is without stopping the simulation process during performing the steady state and transient analysis of the whole system. This controller can modulate the status of the wind turbines in the aggregated model in a given farm according to any change in this farm. By this controller, we save effort and time to change the status of wind turbines in the aggregated model. The proposed wind farm is composed of some smaller farms of permanent magnet synchronous generators (PMSGs) and others of squirrel cage induction generators (SCIGs).
引用
收藏
页码:133 / 142
页数:10
相关论文
共 16 条
[1]  
Ackermann T., 2012, WIND POWER POWER SYS
[2]   Wind Farm Model Aggregation Using Probabilistic Clustering [J].
Ali, Muhammad ;
Ilie, Irinel-Sorin ;
Milanovic, Jovica V. ;
Chicco, Gianfranco .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (01) :309-316
[3]   Evaluating reduced models of aggregated different doubly fed induction generator wind turbines for transient stabilities studies [J].
Andres Garcia, Carlos ;
Fernandez, Luis M. ;
Jurado, Francisco .
WIND ENERGY, 2015, 18 (01) :133-152
[4]  
[Anonymous], [No title captured]
[5]   A novel aggregated DFIG wind farm model using mechanical torque compensating factor [J].
Chowdhury, M. A. ;
Shen, W. X. ;
Hosseinzadeh, N. ;
Pota, H. R. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 67 :265-274
[6]   Aggregate modelling of wind farms containing full-converter wind turbine generators with permanent magnet synchronous machines: transient stability studies [J].
Conroy, J. ;
Watson, R. .
IET RENEWABLE POWER GENERATION, 2009, 3 (01) :39-52
[7]   Reduced model of DFIGs wind farms using aggregation of wind turbines and equivalent wind [J].
Fernandez, L. M. ;
Garcia, C. A. ;
Saenz, J. R. ;
Jurado, F. .
CIRCUITS AND SYSTEMS FOR SIGNAL PROCESSING , INFORMATION AND COMMUNICATION TECHNOLOGIES, AND POWER SOURCES AND SYSTEMS, VOL 1 AND 2, PROCEEDINGS, 2006, :881-884
[8]   Equivalent models of wind farms by using aggregated wind turbines and equivalent winds [J].
Fernandez, L. M. ;
Garcia, C. A. ;
Saenz, J. R. ;
Jurado, F. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :691-704
[9]   Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines [J].
Fernandez, Luis M. ;
Jurado, Francisco ;
Saenz, Jose Ramon .
RENEWABLE ENERGY, 2008, 33 (01) :129-140
[10]   Modelling of wind generation at all scales for transmission system analysis [J].
Hayes, Barry P. ;
Djokic, Sasa Z. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (10) :1144-1154