Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review

被引:67
|
作者
Moureau, Nancy L. [1 ,2 ,3 ]
Flynn, Julie [3 ,4 ]
机构
[1] PICC Excellence Inc, Online Educ, Hartwell, GA 30643 USA
[2] Greenville Hosp Syst, Greenville, SC 29605 USA
[3] Griffith Univ, AVATAR group, Nathan, Qld 4111, Australia
[4] Royal Brisbane Womens Hosp, Brisbane, Qld 4029, Australia
关键词
D O I
10.1155/2015/796762
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background. Needleless connectors (NC) are used on virtually all intravascular devices, providing an easy access point for infusion connection. Colonization of NC is considered the cause of 50% of postinsertion catheter-related infections. Breaks in aseptic technique, from failure to disinfect, result in contamination and subsequent biofilm formation within NC and catheters increasing the potential for infection of central and peripheral catheters. Methods. This systematic reviewevaluated 140 studies and 34 abstracts on NC disinfection practices, the impact of hub contamination on infection, and measures of education and compliance. Results. The greatest risk for contamination of the catheter after insertion is the NC with 33-45% contaminated, and compliance with disinfection as low as 10%. The optimal technique or disinfection time has not been identified, although scrubbing with 70% alcohol for 5-60 seconds is recommended. Studies have reported statistically significant results in infection reduction when passive alcohol disinfection caps are used (48-86% reduction). Clinical Implications. It is critical for healthcare facilities and clinicians to take responsibility for compliance with basic principles of asepsis compliance, to involve frontline staff in strategies, to facilitate education that promotes understanding of the consequences of failure, and to comply with the standard of care for hub disinfection.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] A Successful Approach to Reducing Bloodstream Infections Based on a Disinfection Device for Intravenous Needleless Connector Hubs
    Stango, Claire
    Runyan, Debra
    Stern, John
    Macri, Ida
    Vacca, Maria
    JOURNAL OF INFUSION NURSING, 2014, 37 (06) : 462 - 465
  • [2] A Systematic Review of Needleless Connector Function and Occlusion Outcomes: Evidence Leading the Way
    Moureau, Nancy
    Gorski, Lisa
    Flynn, Julie
    Johnson, Karen
    JOURNAL OF INFUSION NURSING, 2025, 48 (02) : 84 - 105
  • [3] Methods for microbial needleless connector decontamination: A systematic review and meta-analysis
    Flynn, Julie M.
    Larsen, Emily N.
    Keogh, Samantha
    Ullman, Amanda J.
    Rickard, Claire M.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (08) : 956 - 962
  • [4] A prospective clinical study to investigate the microbial contamination a needleless connector
    Seymour, VM
    Dhallu, TS
    Moss, HA
    Tebbs, SE
    Elliott, TSJ
    JOURNAL OF HOSPITAL INFECTION, 2000, 45 (02) : 165 - 168
  • [5] A prospective clinical trial to evaluate the microbial barrier of a needleless connector
    Casey, A. L.
    Burnell, S.
    Whinn, H.
    Worthington, T.
    Faroqui, M. H.
    Elliott, T. S. J.
    JOURNAL OF HOSPITAL INFECTION, 2007, 65 (03) : 212 - 218
  • [6] "Methods for microbial needleless connector decontamination: A systematic review and meta-analysis" - Interpret results with caution
    Glele, Ludwig Serge Aho
    Guilloteau, Adrien
    Astruc, Karine
    Carre, Yolene
    Chaize, Pascal
    Keita-Perse, Olivia
    Lurton, Yves
    Lepelletier, Didier
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (12) : 1520 - 1521
  • [7] AN EVIDENCE BASED PRACTICE PROJECT TO IDENTIFY THE BEST INTRAVENOUS NEEDLELESS CONNECTOR
    Swisher, Marie
    Weaver, Kelly
    Olsen, Mikaela
    ONCOLOGY NURSING FORUM, 2013, 40 (03) : E202 - E202
  • [8] Response to the Letter to the Editor regarding "Methods for microbial needleless connector decontamination: A systematic review and meta-analysis"
    Flynn, Julie M.
    Larsen, Emily
    Keogh, Samantha
    Ullman, Amanda
    Rickard, Claire M.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (12) : 1521 - 1522
  • [9] Adequate Disinfection of a Split-Septum Needleless Intravascular Connector with a 5-Second Alcohol Scrub
    Rupp, Mark E.
    Yu, Stephanie
    Huerta, Tomas
    Cavalieri, R. Jennifer
    Alter, Roxanne
    Fey, Paul D.
    Van Schooneveld, Trevor
    Anderson, James R.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2012, 33 (07): : 661 - 665
  • [10] Impact of needleless connectors in the bloodstream infection: a systematic review
    Frota Mendonca, Silvia Helena
    Lacerda, Rubia Aparecida
    ACTA PAULISTA DE ENFERMAGEM, 2010, 23 (04) : 568 - 573