PERMANENT PACEMAKER SELECTION AND SUBSEQUENT SURVIVAL IN ELDERLY MEDICARE PACEMAKER RECIPIENTS

被引:104
作者
LAMAS, GA
PASHOS, CL
NORMAND, SLT
MCNEIL, B
机构
[1] UNIV MIAMI,SCH MED,MIAMI,FL
[2] HARVARD UNIV,SCH MED,DEPT HLTH CARE POLICY,BOSTON,MA 02115
[3] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DIV CARDIOVASC,BOSTON,MA 02115
关键词
PACING; MORTALITY; PACEMAKERS;
D O I
10.1161/01.CIR.91.4.1063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Dual-chamber pacemakers have been in use for more than 15 years. Although they may confer a physiological advantage over single-chamber Ventricular pacemakers, they are more expensive and have a generally shorter service life than single-chamber devices. We carried out the present study to identify patient subgroups who were preferentially receiving greater or lesser proportions of dual-chamber devices and to determine whether the selection of different types of pacemakers was associated with differences in mortality. Methods and Results We analyzed a 20% random national sample of all Medicare beneficiaries aged 65 years or older who underwent initial placement of a permanent pacemaker and were discharged in 1988, 1989, or 1990 (n=36312). The minimum follow-up for vital status was 1 year. The relation of pacemaker type to patient and provider characteristics was determined using logistic regression analysis. The relation between pacemaker type and mortality was determined using the Cox proportional hazards method. The proportion of dual-chamber systems that were received increased from 27.2% in 1988 to 37.0% in 1990 (P<.001). Dual-chamber pacemaker recipients were younger (P<.001) than ventricular pacemaker recipients. Other independent correlates of dual-chamber pacemaker selection included male sex (odds ratio and 95% confidence intervals, 1.18 and 1.12 to 1.24, respectively), atrioventricular block (1.59 and 1.51 to 1.67), congestive heart failure (1.14 and 1.08 to 1.20), atrial fibrillation (0.36 and 0.34 to 0.39), and the presence of a major noncardiac diagnosis (0.86 and 0.83 to 0.89). Nonmedical predictors of dual-chamber pacemaker selection included Medicaid eligibility (0.78 and 0.71 to 0.86), implantation in the western United States (1.19 and 1.10 to 1.29), implantation by a rural provider (0.70 and 0.65 to 0.76), hospitalization in a 500-bed-or-larger hospital (1.20 and 1.13 to 1.28), hospitalization in a private hospital (1.19 and 1.10 to 1.28), or hospitalization in a hospital with a catheterization laboratory (1.47 and 1.38 to 1.56). Dual-chamber pacemaker selection was an independent predictor of survival at 1 year (0.82 and 0.77 to 0.87) and at 2 years (0.82 and 0.77 to 0.87) after controlling for potentially confounding patient-level and hospital-level characteristics. Conclusions The present study describes important variations in the clinical practice of cardiac pacing, many of which are not based on clinical characteristics. Furthermore, the selection of a dual-chamber pacemaker is associated with increased survival. These results underscore the need for prospective, outcome-based clinical trials of pacemaker mode selection.
引用
收藏
页码:1063 / 1069
页数:7
相关论文
共 35 条
  • [1] COMPARATIVE SURVIVAL AFTER PERMANENT VENTRICULAR AND DUAL CHAMBER PACING FOR PATIENTS WITH CHRONIC HIGH DEGREE ATRIOVENTRICULAR-BLOCK WITH AND WITHOUT PREEXISTENT CONGESTIVE-HEART-FAILURE
    ALPERT, MA
    CURTIS, JJ
    SANFELIPPO, JF
    FLAKER, GC
    WALLS, JT
    MUKERJI, V
    VILLARREAL, D
    KATTI, SK
    MADIGAN, NP
    KROL, RB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) : 925 - 932
  • [2] COMPARATIVE SURVIVAL FOLLOWING PERMANENT VENTRICULAR AND DUAL-CHAMBER PACING FOR PATIENTS WITH CHRONIC SYMPTOMATIC SINUS NODE DYSFUNCTION WITH AND WITHOUT CONGESTIVE-HEART-FAILURE
    ALPERT, MA
    CURTIS, JJ
    SANFELIPPO, JF
    FLAKER, GC
    WALLS, JT
    MUKERJI, V
    VILLARREAL, D
    KATTI, SK
    MADIGAN, NP
    MORGAN, RJ
    [J]. AMERICAN HEART JOURNAL, 1987, 113 (04) : 958 - 965
  • [3] [Anonymous], 1991, Br Heart J, V66, P185
  • [4] ATRIAL KINETICS AND LEFT-VENTRICULAR DIASTOLIC FILLING IN THE HEALTHY ELDERLY
    ARORA, RR
    MACHAC, J
    GOLDMAN, ME
    BUTLER, RN
    GORLIN, R
    HOROWITZ, SF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) : 1255 - 1260
  • [5] RACIAL-DIFFERENCES IN THE USE OF REVASCULARIZATION PROCEDURES AFTER CORONARY ANGIOGRAPHY
    AYANIAN, JZ
    UDVARHELYI, IS
    GATSONIS, CA
    PASHOS, CL
    EPSTEIN, AM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (20): : 2642 - 2646
  • [6] DIFFERENCES IN THE USE OF PROCEDURES BETWEEN WOMEN AND MEN HOSPITALIZED FOR CORONARY HEART-DISEASE
    AYANIAN, JZ
    EPSTEIN, AM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (04) : 221 - 225
  • [7] SURVEY OF CARDIAC PACING IN THE UNITED-STATES IN 1989
    BERNSTEIN, AD
    PARSONNET, V
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (04) : 331 - 338
  • [8] HEALTH PROMOTION AND DISEASE PREVENTION IN THE ELDERLY - COMPARISON OF HOUSE STAFF AND ATTENDING PHYSICIAN ATTITUDES AND PRACTICES
    BLACK, JS
    SEFCIK, T
    KAPOOR, W
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (02) : 389 - 393
  • [9] EFFECTS OF AGING ON ASYNCHRONOUS LEFT-VENTRICULAR REGIONAL FUNCTION AND GLOBAL VENTRICULAR FILLING IN NORMAL HUMAN-SUBJECTS
    BONOW, RO
    VITALE, DF
    BACHARACH, SL
    MARON, BJ
    GREEN, MV
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (01) : 50 - 58
  • [10] GUIDELINES FOR IMPLANTATION OF CARDIAC-PACEMAKERS AND ANTIARRHYTHMIA DEVICES - A REPORT OF THE AMERICAN-COLLEGE-OF-CARDIOLOGY AMERICAN-HEART-ASSOCIATION TASK-FORCE ON ASSESSMENT OF DIAGNOSTIC AND THERAPEUTIC CARDIOVASCULAR PROCEDURES (COMMITTEE ON PACEMAKER IMPLANTATION)
    DREIFUS, LS
    FISCH, C
    GRIFFIN, JC
    GILLETTE, PC
    MASON, JW
    PARSONNET, V
    [J]. CIRCULATION, 1991, 84 (01) : 455 - 467