UMBILICAL ARTERY DOPPLER FLOW-VELOCITY WAVE-FORMS IN RHESUS-ISOIMMUNIZED FETUSES BEFORE AND AFTER FETAL BLOOD-SAMPLING OR TRANSFUSION

被引:7
|
作者
LEGARTH, J [1 ]
LINGMAN, G [1 ]
STANGENBERG, M [1 ]
RAHMAN, F [1 ]
机构
[1] KING FAISAL SPECIALIST HOSP & RES CTR,DEPT OBSTET & GYNAECOL,RIYADH 11211,SAUDI ARABIA
关键词
DOPPLER ULTRASONOGRAPHY; BLOOD FLOW VELOCITIES; FETUS; RH; ARTERIES;
D O I
10.1002/jcu.1870220109
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Pulsed-Doppler examinations of blood-flow velocities in the umbilical artery were carried out before and after 15 diagnostic cordocenteses and 34 fetal blood transfusions into the umbilical vein. There were decreases in the systolic/diastolic ratio (A/B) (p < 0.01), the pulsatility index (PI) (p < 0.05), and the resistance index (RI) (p < 0.01) after cordocentesis but not after fetal blood transfusion. There were no correlations between the initial hematocrit and the umbilical artery Doppler indices in the sample nor in the fetal blood sampling group. In the fetal blood transfusion group, on the other hand, there was a negative correlation between the initial hematocrit and A/B (r = - 0.44; p < 0.01) and the RI (r = - 0.35; p < 0.05). The umbilical artery Doppler flow-velocity indices did not predict the fetal hematocrit. C 1994 John Wiley & Sons, Inc.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] UMBILICAL ARTERY DOPPLER FLOW-VELOCITY WAVE-FORMS AND FETAL ACID-BASE-BALANCE IN RHESUS-ISOIMMUNIZED PREGNANCIES
    LEGARTH, J
    LINGMAN, G
    STANGENBERG, M
    RAHMAN, F
    JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (01) : 37 - 41
  • [2] CHANGES IN BLOOD-FLOW VELOCITY WAVE-FORMS FOLLOWING FETAL BLOOD-SAMPLING
    ZOPPINI, C
    BRIOSCHI, D
    TASSIS, B
    ZULIANI, G
    KUSTERMANN, A
    NICOLINI, U
    FETAL DIAGNOSIS AND THERAPY, 1995, 10 (05) : 315 - 321
  • [3] THE EFFECT OF INTRAVASCULAR TRANSFUSION FOR RHESUS HEMOLYTIC-DISEASE ON UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVE-FORMS
    WELCH, CR
    RODECK, CH
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (09): : 865 - 866
  • [4] UMBILICAL ARTERY VELOCITY WAVE-FORMS BEFORE AND AFTER CHORIONIC VILLUS SAMPLING
    IBBA, RM
    MONNI, G
    OLLA, G
    CAO, A
    PRENATAL DIAGNOSIS, 1994, 14 (09) : 799 - 802
  • [5] THE EFFECTS OF FETAL BLOOD-SAMPLING ON DUCTUS VENOSUS BLOOD-FLOW VELOCITY WAVE-FORMS
    CAPPONI, A
    RIZZO, G
    RINALDO, D
    ARDUINI, D
    ROMANINI, C
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (04) : 241 - 246
  • [6] ERYTHROCYTES IN FETUSES WITH ABNORMAL UMBILICAL ARTERY FLOW VELOCITY WAVE-FORMS
    WILCOX, GR
    TRUDINGER, BJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (02) : 379 - 383
  • [7] DOPPLER UMBILICAL ARTERY FLOW VELOCITY WAVE-FORMS IN DIABETIC PREGNANCY
    JOHNSTONE, FD
    STEEL, JM
    HADDAD, NG
    HOSKINS, PR
    GREER, IA
    CHAMBERS, S
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (02): : 135 - 140
  • [8] FLOW VELOCITY WAVE-FORMS OF THE UMBILICAL AND CEREBRAL-ARTERIES BEFORE AND AFTER INTRAVASCULAR TRANSFUSION
    MARI, G
    MOISE, KJ
    DETER, RL
    CARPENTER, RJ
    OBSTETRICS AND GYNECOLOGY, 1990, 75 (04): : 584 - 589
  • [9] DOPPLER FLOW-VELOCITY WAVE-FORMS IN HUMAN UMBILICAL AND VILLOUS VESSELS - COMPARISON WITH SIMULATED DATA
    TODROS, T
    BASTONERO, S
    GUIOT, C
    LOSANO, G
    PIANTA, PG
    JOURNAL OF PHYSIOLOGY-LONDON, 1993, 459 : P316 - P316
  • [10] EFFECT OF HEMODIALYSIS ON UTERINE AND UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVE-FORMS
    KRAKOW, D